11-2
Siemens PM240-2_EN_rev00-30082019.docx
At this point the system is ready to be used and configured.
Any additional tune-up can be done by acting directly on the values of the parameters of the Drive available
in the list "User" or BOP , as explained in detail in paragraph 11.4 .
ATTENTION: Only in case of change of the inverter or of the electric motor, you must do motor
recognition by P1910, before performing any calibration. Please contact OMARLIFT Service, for the
procedure.
11.3
PARAMETERS LIST
Below are listed the parameters of the list "User " and their default values:
After the modify of the parameters of interest, it is always necessary to save the new values on
the hard memory of the Control Unit
(with button RAM to ROM)
, in order to prevent a loss of data at the
first shut down (voluntary or accidental).
Using WEBSERVER software, you have to switch ONLINE, then
press the push button
RAM to ROM .
Alternatively, see the procedure described to the chapter 10 for the
setup by BOP.
Table 16 List of parameters
ID
Description
Valore
Value
Unità
Unit
MAX
min
SETTING UPWARDS DIRECTION - CONFIGURAZIONE SALITA
p21502
Pre-Start Speed (2.2.2)
0.040
%
0.060
0.020
p21503
Pre-Start Time (2.2.3)
800.000
ms
1000
500
p21507
High Speed (2.2.6)
0.750
%
1.000
0.600
p21512
Low Speed (2.2.7)
0.095
%
0.12
0.060
p21513
Final Dec Time (2.2.14)
4.500.000
ms
6000
3000
p21514
Inspection Speed UP (2.2.9)
0.300
%
0.400
0.100
p21515
Releveling speed UP (2.2.8)
0.120
%
0.150
0.080
SETTING DOWNWARDS DIRECTION - CONFIGURAZIONE DISCESA
p22011
Pre-Start Speed value 2 (2.3.2.2)
-0.002
%
0.020
- 0.020
p22017
Pre-Start Time value 2 (2.3.3.2)
100.000
ms
300
100
p22023
Pre-Start Delay Additional value 2 (2.3.3D.2)
500.000
ms
1000
100
p21537
High Speed (2.3.6)
-0.750
%
-1.000
-0.600.
p21542
Low Speed (2.3.7)
-0.090
%
-0.120
-0.060
p22081
Final Dec Time value 2 (2.3.14.2)
800.000
ms
1000
500
p21544
Inspection Speed DOWN (2.3.9)
-0.300
%
-0.400
-0.100
p21545
Releveling speed DOWN (2.3.8)
-0.020
%
-0.150
-0.080
p21630
Plus Speed while EDV closing
0.080
%
0.120
0.060
RUPTURE VALVE TEST- TEST VALVOLA PARACADUTE
p21523
Parachute function (2.13.1)
0
NA
NA
p21524
Overspeed Factor
1.500
NA
NA
p21525
Ramp-up time (ms) (2.13.3)
2.000.000
ms
NA
NA
p21526
Ramp-down time (ms) (2.13.5)
1.500.000
ms
NA
NA
p21527
Max. Time Parachute (ms)
15.000.000
ms
NA
NA
p21529
Parachute Max.Speed TimeOut (2.13.4)
4.000.000
ms
NA
NA
EMERGENCY MODE - MODALITÀ EMERGENZA
p21546
Emergency Speed Up (2.6.1)
0.200
%
1.000
0.100
p21547
Emergency Speed Down (2.6.2)
-0.150
%
-1.000
-0.100
p21650
Emergency Ramp Adaption
1.000
NA
NA
SHORT FLOOR - PIANO CORTO
Содержание 6SL3210-1PE21-1AL0
Страница 1: ...Siemens PM240 2_EN_rev00 30082019 docx 0 1 0 INVERTER SIEMENS S120 PM240 2 for HI POWER UNITS ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 12: ...3 4 Siemens PM240 2_EN_rev00 30082019 docx Figure 3 PM240 2 frame size FSD FSE ...
Страница 22: ......
Страница 24: ......
Страница 28: ......
Страница 34: ......
Страница 39: ...Siemens PM240 2_EN_rev00 30082019 docx 7 5 ...
Страница 40: ......
Страница 48: ......
Страница 50: ......