background image

 

SIMATIC MV326 
Operating Instructions, 08/2021, C79000-G8976-C644-02 

21

 

Alarm, error and system messages

 

5.1

 

Feedback messages of the optical handheld reader 

 

Situation 

LED displays on the 

optical handheld 

reader 

Acoustic signal  Vibration signal 

SIMATIC MV326 turned on successfully.  All LEDs flash 

 1x 

 1x 

SIMATIC MV326 connected to host 

successfully. 

Wireless symbol 

flashes 

 2x short 

 1x normal 

 1x 

SIMATIC MV326 attempts to connect to 

host. 

Wireless symbol 

flashes fast until 

timeout 

-- 

-- 

SIMATIC MV326 is connected to the 

host. 

Wireless symbol is 

on permanently 

-- 

-- 

SIMATIC MV326 connected to the 

charging station again 

-- 

 1x 

-- 

SIMATIC MV326 does not connect to 

the charging station 

-- 

 3x 

-- 

Decoding and data transfer successful.  Read display flashes 

Wireless symbol 

flashes until data 

transfer is complete 

 1x 

 1x 

Decoding and data transfer not 

successful. 

-- 

 3x 

-- 

Configuration code successfully 

decoded and processed. 

Read display flashes 

 2x 

 2x 

Configuration code successfully 

decoded but not processed. 

Read display flashes 

 4x 

 4x 

SIMATIC MV326 was identified 

-- 

 until random 

button is 

pressed or time 

has expired 

-- 

Содержание 6GF3326-0HT01

Страница 1: ...V326 Operating Instructions 08 2021 C79000 G8976 C644 02 Preface Safety notes 1 Description 2 Commissioning 3 Operate 4 Alarm error and system messages 5 Maintenance and service 6 Technical data 7 Dimension drawings 8 Ordering data 9 Appendix A Service Support B ...

Страница 2: ...rsonnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may...

Страница 3: ...is manual describes the product SIMATIC MV326 This module replaces the previous product SIMATIC MV325 Note the following differences and special features compared to the previous product SIMATIC MV325 The configuration codes listed in the SIMATIC MV326 Configuration Guide 02 2021 cannot be used with the previous product SIMATIC MV325 SIMATIC MV326 does not offer a batch mode buffering of data The ...

Страница 4: ...lso used instead of the full product name SIMATIC MV326 Purpose of the operating instructions Note The operating instructions contain all the important information about the device Read the operating instructions before starting to work with this device Noting and acting on this information Ensures the device functions correctly Saves you service costs These operating instructions contain all the ...

Страница 5: ...networks against cyber threats it is necessary to implement and continuously maintain a holistic state of the art industrial security concept Siemens products and solutions constitute one element of such a concept Customers are responsible for preventing unauthorized access to their plants systems machines and networks Such systems machines and components should only be connected to an enterprise ...

Страница 6: ...Preface SIMATIC MV326 6 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 7: ...4 Operate 19 4 1 Aligning the SIMATIC MV326 optical handheld reader 19 4 2 Enabled and disabled codes in the factory settings 20 4 3 Enabling Suffix Enter 20 5 Alarm error and system messages 21 5 1 Feedback messages of the optical handheld reader 21 5 2 Problems and error correction 22 5 3 Identify reader 23 6 Maintenance and service 25 7 Technical data 27 8 Dimension drawings 31 9 Ordering data ...

Страница 8: ...Table of contents SIMATIC MV326 8 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 9: ...al injury or equipment damage Therefore do not carry out repairs yourself Repairs may only be carried out by authorized qualified personnel at the manufacturer s site Please observe the information in the section Maintenance and service Page 25 Adherence to FCC requirements NOTICE Adherence to FCC requirements for RF radiation To adhere to the FCC requirements relating to the effects of RF radiati...

Страница 10: ...Safety notes SIMATIC MV326 10 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 11: ...nition of all 1D and 2D barcodes as well as barcodes of individual postal services With its patented dual field optics both wide 40 cm and very small 3 cm barcodes can be read With the patented glare control technology codes on shining surfaces can be reliably detected The long life batteries of the device with their fast triggering mechanism measure the battery charge level precisely and show the...

Страница 12: ...th charge display Read confirmation by vibration acoustic and LED signal Fast direction independent reading of 1D and 2D barcodes and barcodes of postal services Compatible with Bluetooth supported Android iOS and Windows mobile devices and tablets The housing which is resistant to disinfectants and has IP65 prevents damage to plastic parts and protects the electronics and optics Paging button sup...

Страница 13: ...ttery Proceed as follows to insert the battery into the device 1 Insert the battery on the back of the device If the battery is inserted correctly it locks in place Proceed as follows to remove the battery 1 Move the slider on the device Result The battery is unlocked 2 Remove the battery in the direction of the arrow ...

Страница 14: ...oximately 50 charged Fully charge the batteries before turning on the device for the first time The charging time for a completely discharged battery with the charging station and the USB cable is about 4 hours Charging the optical handheld reader Proceed as follows to charge the reader 1 Connect the USB cable of the charging station to the USB port of the computer 2 Remove the protective foil on ...

Страница 15: ...d out how much battery charge remains press the button for the charge status Charge status button Charge status displays Table 3 1 Charge status display during charging Charge status display LED state Battery charge status No LED is on 0 One LED is flashing fast 10 One LED is on 25 Two LEDs are on 25 to 50 Three LEDs are on 50 to 75 Four LEDs are on 75 ...

Страница 16: ...tructions 08 2021 C79000 G8976 C644 02 3 3 Switching on the optical handheld reader Proceed as follows to switch on the device 1 Press one of the buttons for 1 s Result The optical handheld reader beeps vibrates and the LEDs are flashing when the device is turned on and ready for operation ...

Страница 17: ...onnection to the base station Follow the steps below for a Bluetooth connection from the charging station to the reader 1 Scan in the QuickConnect code The QuickConnect code is on the front of the charging station Reaction While the connection is being established the green wireless symbol on the charging station and the symbol for a wireless connection at the top of the optical handheld reader ar...

Страница 18: ...Commissioning 3 4 Establishing a Bluetooth connection SIMATIC MV326 18 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 19: ...Keep pressing the button or trigger button The two blue beams sent out by the optical handheld reader are used for targeting 3 The blue beams must be directed to the center of the barcode If the barcode is in the viewing field of the device and at the optimum read distance approximately 10 cm from the device the barcode will be read automatically Result The optical handheld reader beeps and vibrat...

Страница 20: ...x Data Matrix Rectangle All GS1 DataBar Interleaved 2 of 5 PDF417 Macro PDF417 QR code UPC EAN UPC E Codablock F Code 11 Code 32 Composite Data Matrix Inverse Han Xin Code Hong Kong 2 of 5 IATA 2 of 5 Matrix code Matrix 2 of 5 Micro PDF417 MSI Plessey NEC 2 of 5 Pharmacode Plessey Postal Codes Straight 2 of 5 Telepen Trioptic 4 3 Enabling Suffix Enter In the factory settings of the optical handhel...

Страница 21: ...eless symbol flashes fast until timeout SIMATIC MV326 is connected to the host Wireless symbol is on permanently SIMATIC MV326 connected to the charging station again 1x SIMATIC MV326 does not connect to the charging station 3x Decoding and data transfer successful Read display flashes Wireless symbol flashes until data transfer is complete 1x 1x Decoding and data transfer not successful 3x Config...

Страница 22: ...wer indicator of the battery is pressed no LEDs light up on the battery The battery may be empty Charge the battery or swap it for a freshly charged battery Make sure that the LEDs on the battery are flashing during charging Battery malfunction Replace the battery for a working battery The reader beeps three times The reader could not connect to a Bluetooth charging unit Make sure that the chargin...

Страница 23: ...e charging station Press this Page button to identify the reader connected to the charging station By pressing the Page button the connected reader will start beeping by default for 30 seconds You stop the beeping by pressing the Page button again or any other button on the reader When no reader is connected the Page LED on the charging station flashes three times quickly ...

Страница 24: ...Alarm error and system messages 5 3 Identify reader SIMATIC MV326 24 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 25: ...he same way as a digital camera A dirty window could have the result that the optical handheld reader is no longer capable of reading barcodes If the window is dirty clean it with a soft non abrasive cloth or a cosmetic wipe without lotion and not impregnated and a little water You can also use a mild cleansing agent Then wipe the window with a damp cloth Approved cleaning agents The following pro...

Страница 26: ...Maintenance and service SIMATIC MV326 26 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 27: ...417 2D codes Aztec Code Data Matrix Data Matrix Rectangular Extension Grid Matrix Han Xin MaxiCode Micro QR Code QR Code QR Model 1 Proprietary 2D GoCode Optional License Required Postal codes Australian Post Canada Post Intelligent Mail Japan Post KIX Code Korean Post Planet Postnet UK Royal Mail UPU ID tags Optical data Read field Near field 30 horizontal by 20 vertical Wide field 50 horizontal ...

Страница 28: ...A Permitted ambient conditions Degree of protection IP65 Operating temperature 20 55 C Storage temperature 30 65 C Humidity 5 95 no condensation Impact resistance Resistant to being dropped repeatedly on concrete from a height of 1 8 m Resistant to ambient light Up to 96 890 lux Dimensions and weight Dimensions L x W x H Optical handheld reader 131 x 53 x 135 mm Charging station 79 x 79 x 49 mm We...

Страница 29: ... when read The table refers to the AGC factory settings accuracy 10 Table 7 1 Read distances Test code Min mm Max mm 3 mil Code 39 90 112 7 5 mil Code 39 23 172 10 5 mil GS1 DataBar 10 210 13 mil UPC 18 270 5 mil Data Matrix 33 105 6 3 mil Data Matrix 23 140 10 mil Data Matrix 10 170 20 8 mil Data Matrix 18 333 1 mil 0 0254 mm The ideal read distance is about 100 mm Depending on the code type and ...

Страница 30: ...Technical data SIMATIC MV326 30 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 31: ...SIMATIC MV326 Operating Instructions 08 2021 C79000 G8976 C644 02 31 Dimension drawings 8 SIMATIC dimension drawing SIMATIC MV326 charging station dimension drawing ...

Страница 32: ...Dimension drawings SIMATIC MV326 32 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 33: ...ber SIMATIC MV326 Optical handheld reader including battery charging station and USB cable 6GF3326 0HT01 Table 9 2 SIMATIC MV326 accessories ordering data Article number Battery lithium ion 1 300 mAh 50 000 charging cycles 6GF3326 0AC07 Charging station with USB interface Bluetooth wireless interface and USB cable 0 9 m 6GF3326 0AC03 ...

Страница 34: ...Ordering data SIMATIC MV326 34 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 35: ...smission depends on set keyboard Note that the data transmission rate is slower with a set universal keyboard Universal Keyboard Mapping than with selection of a specific keyboard language e g US keyboard SIMATIC MV326 A current list of the codes for configuration of the SIMATIC MV326 optical handheld reader is available at the following link MV326 Configuration Guide https support industry siemen...

Страница 36: ...al handheld reader will only read codes that have exactly the character length you have specified This function is particularly useful when multiple codes with different character lengths are printed on the product that is to be scanned Enabling the function Follow these steps to enable the function 1 Scan the following code to enable the function 2 Scan the QuickConnectCode on the charging statio...

Страница 37: ...V326 Operating Instructions 08 2021 C79000 G8976 C644 02 37 Disabling the function Follow these steps to disable the function 1 Scan the device specific reset code When the reset code is scanned the optical handheld reader is reset to the factory settings and restarted ...

Страница 38: ...es 1 character 2 characters 3 characters 4 characters 5 characters 6 characters 7 characters 8 characters 9 characters 10 characters 11 characters 12 characters 13 characters 14 characters 15 characters 16 characters 17 characters 18 characters 19 characters 20 characters 21 characters 22 characters 23 characters 24 characters A 3 Certificates approvals According to the conditions of the guarantee...

Страница 39: ... a Class B digital device pursuant to part 15 of the FCC Rules The device MV326 6GF3326 0HT01 is equivalent to the CR2702_01 devices from CodeCorp FCC ID HSW2832 CR2702_01 The device MV326 CHARGING STATION 6GF3326 0AC03 is equivalent to the CRA A271_01 device from CodeCorp FCC ID X8WBT840 CRA A271 Industry Canada Radio Standards Specifications RSS 210 Issue 8 December 2010 The device MV326 6GF3326...

Страница 40: ...Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Страница 41: ...ing two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée a...

Страница 42: ...Appendix A 3 Certificates approvals SIMATIC MV326 42 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Страница 43: ...nance and modernization You will find contact data on the Internet at the following address Link https www automation siemens com aspa_app ci yes lang en Industrial Identification homepage You can find the latest general information about our identification systems on the Internet at our Homepage www siemens com ident Online catalog and ordering system The online catalog and the online ordering sy...

Страница 44: ...Service Support SIMATIC MV326 44 Operating Instructions 08 2021 C79000 G8976 C644 02 ...

Отзывы: