Temperature limit (storage / transport in transport
packaging)
-40 ... 70 °C (cyclic)
Temperature limits (operation)
0 ... 45 °C (front)
0 ... 55 °C (rear)
Temperature change (storage/transport in transport
packaging)
Max. 18 K/h
Temperature change (operation)
Max. 30 K/h
Relative humidity limits (storage/transport in trans‐
port packaging)
5 … 95 % at 25 °C
Relative humidity limits (operation)
5 … 80 % at 25 °C
Permissible change in the relative humidity
Max. 0.1 % / h
Pollution degree
2 (indoor use only)
Mechanical environmental conditions (operation)
Vibratory load
3M1 according to EN 60721-3-3
Shock stressing
3M1 according to EN 60721-3-3
1) Connect the device only to a 24 V DC power supply that is compliant with protective extra-low
voltage (PELV) requirements according to UL 61010.
2) Including connecting cables, without connectors to X60/X61
Note
Observe the input data
The 24 V DC power source must be adapted to the input data of the device (see "Electrical data").
NOTICE
Damage to components by coolants and lubricants
The SINUMERIK operating components have been designed for industrial use, particularly on
machine tools and production machines. This also takes into account the use of commercially
available coolants and lubricants. The use of aggressive compounds and additives can damage
components and result in their failure.
Avoid contact between the operating components with coolants and lubricants, as resistance
to all coolants and lubricants cannot be guaranteed.
8.2
Standards and approvals
Approvals
CE approval
Technical data
8.2 Standards and approvals
Machine Push Button Panel: MPP 1500D / MPP 1500E
54
Equipment Manual, 04/2021, A5E50753610B AA