EMERGENCY STOP / enabling button of the handheld unit
Connector designation:
X110
Connector type:
8-pin male connector
Maximum cable length:
30 m
Table 6-2
Assignment of connector X110
Pin
Name
Type
Meaning
1
STOP23
I/O
Emergency Stop NC contact 1.1
2
STOP24
I/O
Emergency Stop NC contact 1.1
3
STOP13
I/O
Emergency Stop NC contact 2.1
4
STOP14
I/O
Emergency Stop NC contact 2.2
5
ZU1P
I
Electrical enabling button 1P
6
ZU1M
O
Electrical enabling button 1M
7
ZU2P
I
Electrical enabling button 2P
8
ZU2M
O
Electrical enabling button 2M
Ethernet connector assignment
Connector designation:
X120, X121
Connector type:
RJ45 socket
Maximum cable length:
100 m
Table 6-3
Assignment of connectors X120, X121
Pin
Name
Type
Meaning
1
TX+
I
Tr
2
TX-
I
Transmit -
3
RX+
O
R
4
N.C.
-
Not assigned
5
N.C.
-
Not assigned
6
RX-
O
Receive -
7
N.C.
-
Not assigned
8
N.C.
-
Not assigned
Optional customer keys (X130)
At connector X130, only connect switches (passive inputs), typically illuminated keys.
The outputs are used to control the lamps in the keys, preferably lamps up to 1.2 Watt or a
maximum of 0.15 A per output.
Connecting up
6.3 Pin assignment of the interfaces
Machine Push Button Panel: MPP 1500D / MPP 1500E
Equipment Manual, 04/2021, A5E50753610B AA
37