Parameters/address space
4.2 Declaration of parameters
Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0)
20
Manual, 03/2019, A5E45488510-AA
IO-Link Manual
If the Vendor ID and Device ID match the connected device, the connected IO-Link device is
automatically started. In other words, in contrast to "IO-Link Autostart", the system checks
here whether the correct device is connected. You need to configure the Device ID / Vendor
ID to enable this.
You need to store the Vendor ID and Device ID of the connected IO-Link device in STEP 7.
In addition, you can select the inspection level for data storage:
●
Identical type (V1.0) without Backup&Restore
●
Type-compatible (V1.1) without Backup&Restore
●
Type-compatible (V1.1) with Backup&Restore
●
Type-compatible (V1.1) with Restore
You can find instructions for determining the Vendor ID and Device ID on the Internet
https://support.industry.siemens.com/cs/ww/en/view/109748852
DI
The port operates as standard digital input.
Deactivated
The port is deactivated.