Technical specifications
5.6 Ambient conditions
IFP2200 INOX MT ETH
Compact Operating Instructions, 07/2021, A5E42185570-AD
39
5.6
Ambient conditions
5.6.1
Transport and storage conditions
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance with these regulations shall render the device warranty void.
Mechanical transport and storage conditions
The following information is for a device that is transported and stored in its original
packaging.
The device was tested according to IEC 60721-3-2 Class 2M4 with the following amendments
and limitations:
Type of condition
Permitted range
Free fall
≤ 1
m
Vibration according to IEC 60068-2-6
5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
250 m/s
2
, 6 ms, 1000 shocks
Climatic transport and storage conditions
The following information applies to a device that is transported in the original packaging
and weather-proof packaging, and stored from some time.
The device was tested according to IEC 60721-3-2 Class 2K11 with the following
amendments and limitations:
Type of condition
Permitted range
Temperature
–20 ... 60 °C
Atmospheric pressure, altitude
1140 ... 660 hPa, corresponds to an elevation of -1000 to 3500 m
Relative humidity
10 ... 90 %
Pollutant concentration
In accordance with ANSI/ISA-71.04-2013 severity level G3
Note
If dewing has developed, wait until the HMI device has dried completely before switching it on.
Do not expose the HMI device to direct radiation from a heater.