Siemens 5WG1 201-2DB12 Скачать руководство пользователя страница 6

Gamma 

instabus

 

Technical product information 

June 2014 

Gamma arina touch sensor                       single 
 

 

double 

 

 

quadruple

 

Technical product information 

 

UP 20x, UP 28x/3 and UP 28x/5 

Update: http://www.siemens.com/gamma 

Subject to change without further notice  

Siemens Building Technologies  

2.16.1.13/6 

Location and function of the display and operat-
ing elements 

 

E1

E5

E4

E6

E2
E3

 

 

E1

E5

E2

E4

E3
E6

 

 
 

E1

E5

E4

E2

E6

E3

 

 
 

E1

E5

E2

E4

E7

E3

E6

 

 

Figure 3: Display and operating elements 

 
E1

 

Upper touch area indicator 

E2

 

LED for status annunciation (not available with UP 
20x/x2, invisible when turns off) 

E3

 

LED for orientation lighting 

E4

 

LED for programming lighting (invisible when turns 
off) 

E5

 

Lower touch area indicator 

E6

 

Labelling field (length: 82 ± 0.15mm, width: 18.35 
± 0.1mm, thickness: < 0.2 mm) 

E7

 

IR receiver hole (UP 203/x5 only) 

 

Installation and wiring 

 

General description

 

The touch sensor is mounted onto the conduit box 
together with its mounting frame. 
The mounting frame is not included and therefore has to 
be ordered separately (see current catalog). 

Mounting 

 

Mount the mounting frame (F1) onto conduit box (G1) 
via mounting slots with mounting screws (F2) (see 
figure 4), 

 

Wiring the KNX connector (H2). 

 

Insert the KNX connector (H2) to the touch sensor (see 
figure 5). Please be noted the polarity of bus 
connection with mark on housing. 

 

Slip the wall switch's main module (F3) together with 
(F4) onto the mounting frame and firmly press them 
together (see figure 6). 
 

 

F1

F3

F4

F2

E6

F5

 

Figure 1: Mounting sequence 

 

F1 

Mounting frame 

F2 

Mounting screws 

F3 

Back housing 

F4 

Front housing 

F5 

Programming button 

E6 

Labelling field 

Содержание 5WG1 201-2DB12

Страница 1: ... 203 2DB13 champagne 5WG1 201 2DB33 5WG1 202 2DB33 5WG1 203 2DB33 with status LED orientation LED scene controller and room temperature sensor ivory white 5WG1 203 2DB14 champagne 5WG1 203 2DB34 with status LED orientation LED scene controller and IR receiver decoder ivory white 5WG1 203 2DB15 champagne 5WG1 203 2DB35 F1 F3 F4 F2 E6 F5 Figure 1 Mounting touch sensor arina E6 Labelling field F1 Mou...

Страница 2: ...pair then this touch area pair may be assigned one of the following functions Dual touch area dimming with stop telegram Dual touch area control of solar protection blinds roller shades Send variable percent value Send variable 8 bit value 1 bit scene control scene 1 and 2 recall save 8 bit scene effect control recall save Forced control Depending on the selected main function another function may...

Страница 3: ... a scene the actuators belonging to that scene must be set to the desired light levels and switch ing states When receiving a save telegram for an 8 bit scene via the 8 bit scene object the scene controller interrogates the current values and states of the actuators via the corre sponding objects and saves these values and states as scene settings for the associated scene number Saved scene values...

Страница 4: ...is identical independent of design and the num ber of touch areas Commissioning Programming mode Press the programing button short 2 s to enable pro gramming mode This is indicated by the programming LED Factory setting When the programing button is pressed very long 20 s the device is reset to the default factory settings This is indicated by evenly flashing the programming LED The flashing stops...

Страница 5: ...LED per touch area for status annunciation e g quadruple switch 8 status LED s IR receiver UP 203 15 UP 203 35 Range of IR transmission approx 20 m under these conditions with IR hand held remote S 425 72 directed in optical direct line of sight at 500 Lux diffuse day light at reception location Connections Bus line Bus terminal black red screwless Ø 0 6 Ø 0 8 mm solid Physical specifications Dime...

Страница 6: ...icator E6 Labelling field length 82 0 15mm width 18 35 0 1mm thickness 0 2 mm E7 IR receiver hole UP 203 x5 only Installation and wiring General description The touch sensor is mounted onto the conduit box together with its mounting frame The mounting frame is not included and therefore has to be ordered separately see current catalog Mounting Mount the mounting frame F1 onto conduit box G1 via mo...

Страница 7: ...unting of the frame F1 Mounting frame F2 Mounting screws G1 Conduit box 86 mm X 86 mm G2 Mounting slots Insert KNX connector H2 Wiring the KNX connector H2 Insert the KNX connector H2 to the touch sensor Please be noted the polarity of bus connection with mark on housing Figure 5 Connect KNX connector F3 Back housing F4 Front housing H1 Pin H2 KNX connector H3 KNX line Installation of main module ...

Страница 8: ...4 Front housing I1 Hole for screwdriver Figure 8 Remove the KNX connector F1 Mounting frame F3 Back housing F4 Front housing H2 KNX connector Remove the back housing F3 Insert screwdriver to the holes J1 and press as showed in Figure 9 Move the back housing out of the mounting frame F1 Pull the KNX connector H2 out from the back housing Figure 9 Remove the back housing F1 Mounting frame F3 Back ho...

Страница 9: ... in mm General notes The operating instructions must be handed over to the client Any faulty device is to be sent together with a return delivery note of the local Siemens office If you have further questions concerning the product please contact our technical support 86 10 4006306090 support ap i bt siemens com Note This product supports two different operation modes KNX and PL Link This document...