Assembly
instructions
ASSEMBLY INSTRUCTIONS
Страница 1: ...HARDWARE DOOR HARDWARE SLIDING DOOR HARDWARE VENTILATION TECHNOLOGY BUILDING TECHNOLOGY BUILDING TECHNOLOGY MHS400 Motorised lift slide system for schemes A and C Assembly instructions ASSEMBLY INSTRU...
Страница 2: ......
Страница 3: ...ting in the lift slide sash 23 2 5 Assembly of the lift drive HA 27 2 6 Assembly of the slide drive SA Schema A 31 2 7 Concealed mains cable fitting and connection Scheme A 33 2 8 Assembly of the ligh...
Страница 4: ...profile cylinder is not required Application The lift drive HA replaces the handle on the lift slide sash Driven by an electric motor it unlocks and lifts the lift slide sash via the lift slide hardw...
Страница 5: ...sash with reference run on first operation of the MHS400 lift slide system High level of functional reliability Tested with 400 kg for more than 20 000 switching cycles Simple cable fitting with cable...
Страница 6: ...059 mm to 6666 mm Sash height standard for HS PORTAL 1175 mm to 2675 mm Sash weight HS PORTAL 200 max 200 kg Sash weight HS PORTAL 300 max 300 kg Sash weight HS PORTAL 400 max 400 kg Max permissible s...
Страница 7: ...ty Contents of slide drive SA box Version 1 1 Slide drive SA Including 24 V power supply 2 1 Catch On slide drive SA 3 1 Catch base For lift slide sash top 4 1 Packer 2 5 5 8 or 10 mm thick depending...
Страница 8: ...00 Assembly instructions Component and accessories overview Scheme A Scopeofdeliveryofindividual components Accessories notincluded in scopeof delivery 11 1 2 3 4 5 7 8 10 10 22 9 16 15 14 19 18 17 13...
Страница 9: ...h weight HS PORTAL 200 max 200 kg Sash weight HS PORTAL 300 max 300 kg Sash weight HS PORTAL 400 max 400 kg Max permissible sash weight for MHS400 lift slide drive max 400 kg Backset gear HS PORTAL 20...
Страница 10: ...l length 7000 mm 7 1 Cover cap SA left For cover profile SA 8 1 Cover cap SA right For cover profile SA 9 2 Cable sash flat ribbon cable 6 wire For slide drive SA lift drive HA 10 24 Cable holder Clip...
Страница 11: ...by lift slide sash Use profile connectors to connect the cover profiles SA on the left and right at and above total length of 7000 mm Scopeofdeliveryofindividual components Accessories notincluded in...
Страница 12: ...systems The infrared remote control can control up to 5 drive groups separately With scheme C each lift slide sash can also be controlled individually To achieve this several MHS400 lift slide systems...
Страница 13: ...ring lift slide elements make sure that no parts of the body or objects are under the lift slide sash Do not leave children unattended near a lift slide element Risk of injury or death due to electric...
Страница 14: ...and electrical work must be complied with and the safety instructions in our product documentation must be followed Please read these assembly instruc tions carefully and in full before assembling and...
Страница 15: ...mm plus 15 mm timber or metal drill Phillips screwdriver size 2 1 screwdriver bit 90 mm long 2 screw clamps Folding rule Router for timber elements Between 2 and 4 assembly racks Watch with second han...
Страница 16: ...ermines the traverse path and the traverse forces of the lift slide sash automatically see operating instruc tions Prior to assembly clarify how the MHS400 system is to be controlled in addition to us...
Страница 17: ...raverse path and the traverse forces of the lift slide sash automatically see operating instruc tions Prior to assembly clarify how the MHS400 system is to be controlled in addition to using the infra...
Страница 18: ...e carried out before starting work For scheme A the concealed mains cable guide must always be located on the horizontal top section of the lift slide frame near the locking side For scheme C the conc...
Страница 19: ...he cable outlet for scheme A is always at the top of the slide drive SA on the locking side Fig 1 for scheme C it can be located on the outside of the slide drive SA on either the left hand side or th...
Страница 20: ...ty isolation is required if the customer is fitting the mains cable The isolated end of the mains cable must be located inside the power supply housing scheme A or 5 pin socket scheme C The connection...
Страница 21: ...orizontally at the top noting the drilling diameter Fig 3 1 2 3 300 416 X 10 5 29 0 2 50 8 Positioning and drilling dimensions for the drilled holes for the catch on the lift slide sash fig for timber...
Страница 22: ...lling to 15 mm Fig 5 and 6 The through hole can be drilled with the through hole jig MHS400 see Fig 6 this is available as an accessory Through holes do not have to be drilled for lift slide PVC and a...
Страница 23: ...rive unit into the square mount on the lift slide hardware gear and align on the lift slide sash Fig 1 Mark the external edges of the fixing plate HA Fig 2 Take the lift drive HA off the fixing plate...
Страница 24: ...lift drive HA to the fixing plate HA do not screw Insert the square of the drive unit into the square mount on the lift slide hardware gear and align on the lift slide sash Fig 1 Mark the external edg...
Страница 25: ...he scope of delivery in the lift slide hardware gear and in the sash groove at the top of the lift slide sash The cable holders included in the scope of delivery clip into the lift slide hardware gear...
Страница 26: ...Then secure with cable holders page 24 Fig 1 and 2 With timber elements the cable is fed through the through hole 15 mm Fig 6 WithPVCandaluminiumelements thecableis ifnecessary routedintothesashgroov...
Страница 27: ...he sash groove can be milled 5 mm deeper on the horizontal sash timber at the top The bearing surface of the guides must not be altered In the case of retrofitting flat washers 20 mm and nails max 30...
Страница 28: ...Fig 3 and pull back as far as a length of 50 mm Fig 5 Place the catch base and if applicable the packer depending on profile included in scope of delivery on the sash Fig 4 Use cable holders to secure...
Страница 29: ...read M5 on recessed pull handles by other manufacturers can in some cases prevent manual operation with the emergency operating handle In such cases the recessed pull handle must be replaced with the...
Страница 30: ...f the drive unit Fig 2 Attaching and screwing on the cover caps HA Unscrew the two screws in the centre of the drive unit then set the top half of the cover cap HA down on the fixing plate HA and care...
Страница 31: ...handle cover for example can be covered with the lock cover rose 27 which is available as an accessory A 27 Countersunk bolts St 2 9 x 11 mm Option B Lift slide sash with cylinder lock cylinder lock...
Страница 32: ...profile Position the rose lock 26 accessory on the lift slide sash underneath the lift drive HA and fix in place with 2 countersunk bolts St 2 9 x 11 mm included in scope of delivery Fig 1 For alumin...
Страница 33: ...e by 2 mm see Fig A 2 mm 2 mm 2 mm A Fig for positioning DIN left DIN right is a mirror image Inside frame edge External edge mounting angle Frame inside edge slide drive SA Cover caps SA Cowl length...
Страница 34: ...to the mounting angle at screw level A or B Fig 1 Set the catch down on the catch base and screw on with suitable screws Fig 2 see the table on page 13 Connect the cable sash flat ribbon cable 6 wire...
Страница 35: ...the power supply cover Fig 1 Disassemble and remove the plug cable that comes as standard in the power supply Fig 2 Run the concealed mains cable through the notch in the mounting angle and into the p...
Страница 36: ...Modifications to the MHS400 system are required for operation with a light curtain On the slide drive SA a jumper must be switched for operation with a light curtain Terminal board for connecting lig...
Страница 37: ...ccount when measuring the inside frame width Each RIB must be calculated individually for the left hand slide drive SA dimension 1 and the right hand slide drive SA dimension 2 To check that the measu...
Страница 38: ...wed on as appropriate for the installation situation of the lift slide profile system concerned see Chapter 4 Fixing the slide drives SA to the mounting angle at screw level A or B Fig 1 Set the catch...
Страница 39: ...ng Fig 6 Attach the cover profile SA to the mounting angle Fig 7 Use profile connectors to connect the cover profiles on the left and right at and above total length of 7000 mm Fig 8 Press down on the...
Страница 40: ...ug Fig 1 Unplug and remove the 2 wire mains plug cable that comes as standard in the power supply Fig 2 Route the concealed mains cable through the open cable duct clips open and shut and cable duct r...
Страница 41: ...11 Assembly of the light curtain Scheme C Modifications to the MHS400 system are required for operation with a light curtain On the slide drive SA a jumper must be switched for operation with a light...
Страница 42: ...the lift slide element following assembly of the MHS400 system e g changes to stoppers end pieces etc Seals on lift slide element too stiff or not fitted correctly Seal lip is rubbing against the gui...
Страница 43: ...on the following pages Screw levels Mounting angle for slide drive SA shown without drive unit A B Adjustment dimension X The dimension X represents the set value for the height clearance between the...
Страница 44: ...01 02 Timber element with guide rail KH 0130 01 X A 56 171 20 7 18 5 73 11 45 34 91 68 107 68 92 47 25 72 Screw level A Dimension X 29 mm Packer 8 mm Reinforcement None Use flat washers see Chapter 2...
Страница 45: ...pdate 17 12 2014 43 Assembly instructions MHS400 Timber element with guide rail HH 03 56 212 92 107 92 92 34 118 18 7 X 36 Screw level A Dimension X 25 mm Packer None Reinforcement None Guide rail HH0...
Страница 46: ...KF element Aluplast HST 4000 KF element Aluplast Ideal A 73 72 47 25 45 7 22 5 25 X Screw level A Dimension X 37 mm Packer None Reinforcement None Run flat ribbon cable through profile chamber Profil...
Страница 47: ...embly instructions MHS400 KF element Inoutic KF element Gealan S 8000 X 45 30 Screw level A Dimension X 31 mm Packers None Reinforcement None X B 73 20 45 47 25 5 72 Screw level B Dimension X 31 mm Pa...
Страница 48: ...45 10 40 15 10 t 50 10 22 73 Screw level A Dimension X 44 mm Packer 10 mm Reinforcement None Profile with cover Insert screw on accessory Screw on accessory made from Packer X A 27 47 72 45 25 22 5 7...
Страница 49: ...0 KF element Salamander Design iD KF element Sch co Corona CT 70 HS A 72 47 29 29 5 45 12 73 X Screw level A Dimension X 29 mm Packer None Reinforcement None B 72 15 47 25 45 20 11 12 1 73 X Screw lev...
Страница 50: ...element Rehau S 785 Brilliant Design X A 72 47 25 45 40 11 5 13 5 73 Screw level A Dimension X 39 mm Packers 8 mm 5 mm Reinforcement None Profile with cover Packers X B 72 47 25 20 45 5 11 73 Screw le...
Страница 51: ...e KF element Veka Topline and Softline 70 B 72 47 25 9 5 18 45 15 73 X Screw level B Dimension X 35 mm Packer None Reinforcement None A 72 47 25 19 5 10 45 73 28 X Screw level A Dimension X 29 mm Pack...
Страница 52: ...tructions KF element Veka Slide 70 KF element Thyssen Polymer 50 25 165 90 X 5 6 29 5 26 5 Screw level A Dimension X 32 mm Packer None Reinforcement None A 9 72 47 25 23 5 6 45 73 X Screw level A Dime...
Страница 53: ...top for aluminium elements LM element ALCOA RT 135 LM element Alcoa Kawneer 3572 11 5 72 47 25 12 20 45 73 Screw level B Dimension X 35 mm Packer 5 mm Reinforcement None Note doubling up Packer Doubl...
Страница 54: ...Hueck 5 2 72 47 25 14 20 45 73 Screw level B Dimension X 35 mm Packer 5 mm Reinforcement None Profile with cover Note doubling up Packers Doubling up X B 72 47 25 10 20 45 73 Screw level B Dimension X...
Страница 55: ...LM element Heroal 070 LM element Heroal S77 Hi X B 15 72 47 25 20 10 45 73 Screw level B Dimension X 36 mm Packer None Reinforcement None Note doubling up Doubling up 77 24 X 11 6 14 6 14 6 Screw lev...
Страница 56: ...instructions LM element Reynaers CP 130 LM element Reynaers CP 155 LS Duorail 5 5 X 25 40 Screw level A Dimension X 54 mm Packer 5 mm Reinforcement None X B 7 72 47 25 10 20 45 73 Screw level B Dimens...
Страница 57: ...5 2 5 8 X 21 Reinforcement 2x38 mm Screw level B Dimension X 38 mm Packer 2 5 mm Reinforcement None X B 8 8 12 72 47 25 20 20 45 73 Screw level B Dimension X 37 mm Packer 8 mm Reinforcement None Inser...
Страница 58: ...lement Sch co ASS 70 HI formerly Royal S 160 HI B 14 7 5 72 47 25 16 20 45 73 X Screw level B Dimension X 37 mm Packer 5 mm Reinforcement None Profile with cover Note doubling up Doubling up Packer X...
Страница 59: ...element Wicona WSL 160 LM element Wicona Wicslide 23 160 10 X 50 8 14 5 Screw level A Dimension X 39 mm Packer 5 mm Reinforcement None X B 5 18 10 72 47 25 3 20 45 73 Screw level B Dimension X 35 mm...
Страница 60: ...58 Last update 17 12 2014 MHS400 Assembly instructions LM element Aluprof MB 77 77 X 15 33 45 174 Screw level A Dimension X 34 mm Packer None Reinforcement None...
Страница 61: ...are warranted for a period of two years subject to correct installation and proper use in accordance with statutory provisions As part of our ongoing improvements we reserve the right to replace indiv...
Страница 62: ...rotocol 14 315 The machine may only be put into operation when incomplete if it has been ascertained if applicable that the machine into which the incomplete machine is to be installed conforms to the...
Страница 63: ......
Страница 64: ...elux Phone 32 9 2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland...