12
MSA400 smart
Installation and operating instructions
05.2017
7.4 Drill holes on the sliding sash
7.4.1 Positioning and setting the catch jig (accessories)
Place the jig horizontally at the top of the lift & slide sash (Fig. 1), removing existing sash seals first. Position and set the jig in
accordance with the dimensioning (Fig. 2).
Make the holes for the catch horizontally at the top, noting the drilling diameter (Fig. 3).
1
2
3
300
(416)
X
10,5
29
-0,2
50
8
Positioning and drilling diameters for the holes of the catch on the
Sliding sash (fig. for timber profile DIN left - DIN right is a mirror image)
Adjustment dimension
X
Cable feed-through
Ø 15
Supporting peg
Catch base Ø 7
Screw holes Ø 3
Hole Ø 3
for fixing screws
for catch
Hole Ø 7
for supporting peg for
catch base
Hole Ø 15
for cable feed-through
Important:
In order for the catch to be positioned correctly on the sliding sash, the set dimension
X
(Fig. 2) must be used.
The correct set dimension
X
for the respective profile systems is listed in the installation steps for the installation of the
MSA400 smart, available from our download portal: