Original operating instructions
10.2018
15. Technical specifications
The values can vary according to the specific equipment configuration.
AEROMAT VT WRG 1100
Var. 1
Var. 2
Var. 3
Var. 4
Sensors
―
―
WLAN module
―
―
Sound absorption (with sliders open)
1)
R
w-1.9
= 48 dB
D
n,e,w
= 55 dB
Max. permissible area load per linear metre of ventilator length
1,000 kg
Heat transition coefficient
2)
U = 0.55 W/m
2
K
Permissible operating temperature
‒15 °C to +40 °C
Outside air filter (if present)
F7, 193 x 88 mm
Exhaust air filter (if present)
G3, 330 x 90 mm
Effective air throughput
(with filter)
With blower level 1
With blower level 2
With blower level 3 (power level)
approx. 21 m
3
/h
approx. 37 m
3
/h
approx. 56 m
3
/h
Heat recovery efficiency
3)
max. 62%
Inherent noise
4)
at blower level 1
With blower level 2
With blower level 3 (power level)
L
pA
= approx. 21 dB(A)
L
pA
= approx. 27 dB(A)
L
pA
= approx. 38 dB(A)
Supply voltage
230 V∼
Unit operating voltage
24 V
Power consumption
With blower level 1
With blower level 2
With blower level 3 (power level)
4 W
7 W
18 W
5 W
8 W
20 W
Mains supply
230 V
∼
/ 50 Hz
Protection class II
Thermal protection in transformer
Length of connecting cable
1.50 m or 5 m
1)
Measured in accordance with DIN EN 10140‒2 at an overall depth of 320 mm.
2)
calculated according to DIN EN ISO 6946.
3)
Based on EN 308.
4)
Measured in accordance with DIN EN ISO 3745 (with room insulation 8 db).
15.1 Dimensions
LL
BT
100 mm
B
A
room side
Ventilator length (LL)
1,100 to 1,400 mm, cable outlet A = 225 mm
1,401 to 3,000 mm, cable outlet B = 80 mm
Installation depth (BT)
Min. 380 mm (subject to weather grille variant)