Siebeck GmbH
Translation of the original operating manual
0411 FRT-A-MKIIIbed
Page
8
Safety !
The European standard EN 60204-1 requires the power
supply connection to be established by a suitable plug device.
The power supply cable must not be connected to a power
distributor directly by way of a terminal connection, without a plug
connector.
Safety limit switch S1 prevents the machine from starting up when
the machine hood is open. This safety device must be checked
before putting the machine into operation each time to make
sure it is fully functional.
Procedure:
First switch on the machine and wait for the reference run to be performed (see
last paragraph below), open the hood, do not reach into the machine (!), then
press the foot pedal. The machine must not start up.
Monitoring switch B7 prevents the machine from starting up if the
dirt pan is removed or not fully inserted. This monitoring device
must be checked before putting the machine into operation each
time to make sure it is fully functional. Procedure as described
above.
Always pull the mains plug before all maintenance and cleaning
work!
When inserting a new string bobbin, and when threading the string,
always pull the mains plug.
Reference run
Once the machine has been switched on using the master switch (Q1), a check
is automatically performed to determine whether the preset reference points for
the ring and knotting aggregate drives are positioned correctly. This run
(duration approx, 10 seconds) is performed at reduced speed and ensures that
both drives are ideally synchronised with each other. The machine is ready for
operation on completion of this reference run.
A minimum of 500 lux is required for local lighting.