Siebeck GmbH
Translation of the original operating manual
0411 FRT-A-MKIIIbed
Page 43
TROUBLESHOOTING
Cause
Remedy
Knot pattern is not correct
String break
Machine does not start up
Knotting aggregate does not
start up
Ring does not switch off in
accordance with set
preselection
Knotting aggregate does not
switch off after one turn
See "The story of knots" on pages 38-39,
String taking the wrong course, page 17-23
1.
Refer to the chapter "Set-up and
commissioning, pages 12-14
2.
Check the foot switch B1
3.
Check the ring and knotter motor
4.
Check the fuse F1
5.
Check the safety sensor (S1) on the
hood and
monitoring switch (B7) on the drip tray
Check the spacing between the trigger
and the proximity switch B5, switching
distance = 2mm
Check the spacing between the trigger
and the proximity switch B4, switching
distance = 2mm
Check the spacing between the trigger
and the proximity switch B5, switching
distance = 2mm
The knotting aggregate cannot
Check the fuse F1
be moved in jog mode