Drive Amplifier SD2M
Device variant 03622xxxx
80AF
81BF
82AF
83BF
DC link
Minimum
[V
DC
]
283
566
325
325
DC voltage
Maximum
[V
DC
]
750
750
750
750
Capacity of DC link
[mF]
12
24
1.1
2.2
Logic unit
Power consumption at 24 V
[W]
50
75
50
75
Minimum
[V
DC
]
18
18
18
18
Logic supply
(5)
(2.5 A)
Maximum
[V
DC
]
28
28
28
28
Power unit
Max. power loss at rated power
[%]
4
4
4
4
Min. external ballast resistor
[Ω]
6
3.3
–
–
Max. power of external ballast resistor t < 2
s
[kW]
106
219
–
–
Ballast threshold
[V
DC
]
800
800
–
–
Overvoltage threshold
[V
DC
]
850
850
850
850
Undervoltage threshold
[V
DC
]
40
40
40
40
Environment
Minimum
[°C]
5
5
5
5
Temperature
Maximum
(6)
[°C]
40/60
40/60
40/60
40/60
Max. humidity without bedewing
[%]
85
85
85
85
Device
IP code
IP20
IP20
IP20
IP20
Max. temperature of the output stage
[°C]
75
75
75
75
Weight
[kg]
47
93/117
(7)
47
90
(1)
This value applies for 3-phase mains supply of 400 V
AC
.
(2)
This value applies for a DC voltage supply of 600 V
DC
.
(3)
The current is limited linearly between derating frequency and 0 Hz (see
).
(4)
No inrush current limitation is necessary for this device.
(5)
It is essential that the logic is supplied with voltage (see
(6)
100 % rated current up to an ambient temperature of 40 °C. At an ambient temperature between 40 °C to 60 °C the power
must be reduced by 1.5 % per 1 °C.
(7)
The device only has a weight of 93 kg; the device incl. DC link extension 036225000 has a weight of 117 kg.