![SIEB & MEYER 0SD4S Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/sieb-and-meyer/0sd4s-series/0sd4s-series_hardware-description_1264955091.webp)
The following parameters are achieved according to the safety case:
▶
according to EN ISO 13849-1:2008-12
– MTTFd: >100 years
– DC = 99%
– Category 4
– Performance Level e
▶
according to EN 61508-1:2010 and EN 61800-5-2:2014-06
– PFH = 0
– SFF = 100 % (if there are PFH values, then SFF<100%)
– HFT = 0
The safety concept K3 meets the requirements of SIL 3 according to the standards
named above.
Requirements according to DIN EN 61800-5-2:2014-06
When connected appropriately, the safety concept K3 does not supply any share of dan-
gerous, undetected errors in the safety chain for the function STO.
Thus the stop function 0+1 according to DIN EN 60204-1 is realized.
91
Drive System SD4S - Hardware Description
Functional Safety