38

18. WARRANTY

Sidhil Ltd guarantees this product is free from defects in material and workmanship under normal use for 5 
years (1 year full parts and labour, 4 further years parts only) from the date of purchase from Sidhil Ltd, its 
subsidiary companies, authorised dealers and international distributors. Proof of purchase must be presented 
with any claim. Except as provided herein, Sidhil Ltd, product warranty does not cover damage caused by 
misuse or abuse, accident, the attachment of any unauthorised accessory, alteration to the product, or any 
other conditions whatsoever that are beyond the control of Sidhil Ltd.  Sidhil Ltd, its subsidiary companies, 
authorised dealers and international distributors shall have no liability or responsibility to customers or any 
other person or entity with respect to any liability, loss or damage caused directly or indirectly by use or 
performance of the product or arising out of any breach of this warranty, including but not limited to any 
damages resulting from inconvenience, loss of time, property, revenue, or profit or any indirect, special, 
incidental or consequential damages, even if Sidhil Ltd, its subsidiary companies, authorised dealers or 
international distributors have been advised of the possibility of such damages.

In the event of a product defect during the warranty period you should contact your supplier, whether it 
be  Sidhil Ltd, its subsidiary companies, authorised dealers or international distributors who will at their 
option unless otherwise provided by law; a) correct the defect by product repair without charge for parts 
and labour b) replace the product with one of the same or similar design or c) refund the purchase price.  
All replaced parts and products on which a refund is made become the property of Sidhil Ltd.  New or 
reconditioned parts and products may be used in the performance of the warranty service.  Repaired or 
replaced parts and products are warranted for the remainder of the original warranty period.  You will be 
charged for repair or replacement of the product made after the expiration of the warranty period.

This warranty does not cover; a) damage or failure by or attributes to acts of God, abuse, accident, misuse, 
improper or abnormal usage, failure to follow instructions, improper installation or maintenance, alterations, 
lightning or other incidence of excess voltage or current, b) any repairs other than those provided by a Sidhil 
Ltd authorised technician, c) consumables such as fuses, d) cosmetic damage, e) transportation, shipping 
or insurance costs or f) costs of product removal, installation setup service adjustment or re-installation.

This limited 5 year warranty gives you specific legal rights and you may also have other rights.

Sidhil Ltd cannot be held responsible for any injury or incident which relates to the use of this bed in 
conjunction with accessories manufactured by companies other than Sidhil Ltd.

All products carry the CE mark in accordance with EC Directive on Medical Devices (93/42/EEC).

Sidhil has a policy of continual product improvement and reserves the right to amend specifications covered 
in this document.

No part of this document may be reproduced without the written approval of Sidhil Ltd.

Содержание Solite UK

Страница 1: ...Instructions for use Community Care Bed Range www sidhil com...

Страница 2: ...levels of environmental awareness and sustainability across our manufacturing operation At Sidhil everything we do is designed around quality From our modern and efficient manufacturing plant in Halif...

Страница 3: ...ecking the Bed 16 9 OPERATION OF THE BED 17 9 1 Operational Limits 17 9 2 Installation Preparing For Use 17 9 3 Brake System 19 9 4 Side Rails and Mattresses 20 9 5 Side Rail Safety 20 9 6 Electrical...

Страница 4: ...contact your provider or if in doubt contact Sidhil Ltd at the following address Please quote the Solite UK serial number on all correspondence Sidhil Ltd Sidhil Business Park Holmfield Halifax West Y...

Страница 5: ...designed to provide patients with optimum independence and freedom of movement through the use of a touch button handset Thebedoffersgreatlyreducedmanualhandlingrequirementsforthecarerbyproviding a b...

Страница 6: ...to four separate sections Transport stand to aid storage and bed transportation Electrical system IPX4 rated Splash resistant Battery backup functionality SOLITE UK 4 BB only If patient requirements a...

Страница 7: ...Before a patient uses the bed a risk assessment must be performed on a patient by patient basis The risk assessment should include but is not limited to Entrapment Falling out of the bed Children and...

Страница 8: ...xplosion fire Bed functions must be locked out if there is any doubt about the ability of the patient to operate the bed safely If children adults with learning difficulties or even pets pose a potent...

Страница 9: ...on their side Ambient temperature 10 C to 50 C Humidity 20 90 at 30 C not condensing Atmospheric pressure 800hPa to 1060hPa altitude 2000m The bed is not intended for patient transport it is not to be...

Страница 10: ...mage is noticed to any electrical component turn off at the mains and contact your provider or Sidhil Ltd immediately Mattress suitability Refer to section 17 Type B Applied Part Applied Part The part...

Страница 11: ...ket 3 Castor 4 Leg section 5 Control box back rest actuator 6 Leg rest actuator 7 Extension hand wheels 8 Locking collar 9 High low actuator 10 Backrest section Transport stand not shown 7 PARTS IDENT...

Страница 12: ...carefully place it flat on the floor Loosen the hand wheels on the leg section attaching it to the transport stand and then lift this section off the stand and carefully place it flat on the floor Tur...

Страница 13: ...rs Bring both halves of the bed together and align each section so that the spigots in the backrest section locate into the open tube ends in the leg section Pull the two sections together and tighten...

Страница 14: ...able has enough flex to allow full movement of the actuator Note The two bed ends are identical however plugging them into the correct port is important Note the location of the correct end before plu...

Страница 15: ...unction is not functioning as expected the cables may have been incorrectly located double check against the diagram on the control box Caution 8 5 Ancillary Product Cable Routing When fitting ancilla...

Страница 16: ...slack in the cables to allow for movement Is the bed clear of obstructions Have the 2 clevis pins been passed through the bed s central joint and secured with R clips Has a risk assessment been perfo...

Страница 17: ...mbs are clear of moving parts The mains plug is the disconnect device for the means of isolating the bed from the mains supply the plug must be accessible at all times Ensure the mains cable is plugge...

Страница 18: ...tc being evident to minimise the risk of them being swallowed by a baby child or the bed occupant and creating a choking hazard Keep the bed away from sources of heat and naked flames e g cigarettes f...

Страница 19: ...obstacles such as over bed tables and other furniture are not causing an obstruction Ensure the bed is positioned an appropriate distance from walls other furniture to prevent damage or patient injur...

Страница 20: ...fe Side side rail in some circumstances It is the equipment provider s responsibility to ensure suitability for use Whilst every care has been taken to ensure that the design of Sidhil s side rails me...

Страница 21: ...l Warning Caution Ensure a risk assessment is undertaken to ensure the suitability of the occupant using the handset If patient requirementsare such that Trendelenburgfunctionality is deemed to pose a...

Страница 22: ...function if a patient could be injured due to inadvertent motion of the mattress platform The lockout function on the handset is to be used at the discretion of the carer If children adults with lear...

Страница 23: ...ght not important Lift the leg section a little so that the support bow releases from the channel and rests on the supporting tube Gently lower the leg section down The knee break angle will now becom...

Страница 24: ...its clip To Extend the Platform Loosen by 3 4 turns the two hand wheels located on the platform section Slide the platform extension out to the correct length to suit the mattress and extension block...

Страница 25: ...g both halves of the bed frame split the bed in half and gently lower onto the floor Unlock both locking collars on one end collar must be lifted before turning Whilst supporting the bed end lift the...

Страница 26: ...through the larger open tubes on the side of the transport stand brackets ensuring the electrics are facing inwards Carefully lift the leg section and lower the open end onto the vertical tubes ensuri...

Страница 27: ...on Hold support the section Remove the pins that hold the actuator in place Gently lower the section s to the flattened position 12 BATTERY CHARACTERISTICS SOLITE UK 4 BB ONLY The internal battery tri...

Страница 28: ...atically moving to the dirtiest parts Extra care should be taken around areas where excess dirt or dust may gather The cloth should be changed during the cleaning process if it becomes soiled Rinse do...

Страница 29: ...team cleaned The individual manufacturer s instructions shouldbefollowedwhenusingasteamcleanerandthefollowingprecautionsobserved Avoid directing steam directly at electrical components and reduce stea...

Страница 30: ...on light on the control box is lit if not replace fuse Actuator handset leads not plugged in Check plug connections on the control box and actuators Damage to mains cable actuator cable or handset cab...

Страница 31: ...n the handset Check that all electrical cables are in good condition Check the retaining clip is fastened to the control box securing the electrical cables in place Checkthattheredretainingringiscorre...

Страница 32: ...e bed frame is not to be disposed of in general municipal waste Some of the electrical components could be harmful to the environment and where viable the components can be recovered and reused recycl...

Страница 33: ...ication environment 3 and 4 Shock and vibration To be used on a flat level floor e g vinyl carpet laminate based UV Intended for indoor use only 70 27 24 Warning If patient requirements situation are...

Страница 34: ...ronic equipment however interference to sensitive equipment is possible Qualified users of the Solite UK Bed can help prevent electromagnetic interference by maintaining a suitable distance between po...

Страница 35: ...side side rails SOLITE SR 2 Grange side rails GRANGE SR Universal standard side rails UNIVERSAL SR MAG Universal high side rails UNIVERSAL SR HI MAG Side rail pads 1316 PS CREAM Universal high side r...

Страница 36: ...mm 152mm 53 58kg m Softrest Contour MAT SOFT CON 1990mm 864mm 152mm 35 37kg m Softrest Thin MAT SOFT THIN 1990mm 864mm 64mm 38 40kg m Essential Foam MAT BASIC 1990mm 864mm 127mm 30 33kg m Foam Extensi...

Страница 37: ...the top of the side rail It is essential that a patient risk assessment is performed to ensure that this does not introduce a hazard to the patient Sidhil recommends setting the pressure of the Solo I...

Страница 38: ...provided by law a correct the defect by product repair without charge for parts and labour b replace the product with one of the same or similar design or c refund the purchase price All replaced part...

Страница 39: ...39 NOTES...

Страница 40: ...STRUC SOLITE UK 16 01 2015 Rev 9 CONTACT INFORMATION Tel 44 0 01422 233000 Fax 44 0 01422 233010 Email sales sidhil com www sidhil com Sidhil Business Park Holmfield Halifax HX2 9TN A member of the Si...