13
Stabilizer Operation and User guide
version 5288-2 - 2018
SCU-1x
45010.102.200
FCU Centering normal Fin
stern port Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45010.103.200
FCU Centering normal Fin
stern starboard Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45011.100.200
FCU Centering fast Fin bow
port Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45011.101.200
FCU Centering fast Fin bow
starboard Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45011.102.200
FCU Centering fast Fin stern
port Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45011.103.200
FCU Centering fast Fin stern
starboard Timeout
FCU did not manage to center the fin
within 10seconds.
-Check if a PHC-3 fault is
present.
-Check encoder belt and
pulleys.
L2
45012.100.200
FCU FW upgrade Fin bow
port Timeout
SCU failed to upgrade the FCU FW.
-Check cabling between SCU
and FCU
-Consult Side-Power dealer
L2
45012.101.200
FCU FW upgrade Fin bow
starboard Timeout
SCU failed to upgrade the FCU FW.
-Check cabling between SCU
and FCU
-Consult Side-Power dealer
L2
45012.102.200
FCU FW upgrade Fin stern
port Timeout
SCU failed to upgrade the FCU FW.
-Check cabling between SCU
and FCU
-Consult Side-Power dealer
L2
45012.103.200
FCU FW upgrade Fin stern
starboard Timeout
SCU failed to upgrade the FCU FW.
-Check cabling between SCU
and FCU
-Consult Side-Power dealer
L2
45013.100.13
FCU Float valve Fin bow port
Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45013.100.16
FCU Float valve Fin bow port
Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45013.101.13
FCU Float valve Fin bow
starboard Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45013.101.16
FCU Float valve Fin bow
starboard Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45013.102.13
FCU Float valve Fin stern
port Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45013.102.16
FCU Float valve Fin stern
port Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45013.103.13
FCU Float valve Fin stern
starboard Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45013.103.16
FCU Float valve Fin stern
starboard Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45014.100.13
FCU Lock valve Fin bow port
Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45014.100.16
FCU Lock valve Fin bow port
Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45014.101.13
FCU Lock valve Fin bow
starboard Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45014.101.16
FCU Lock valve Fin bow
starboard Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45014.102.13
FCU Lock valve Fin stern
port Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45014.102.16
FCU Lock valve Fin stern
port Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
45014.103.13
FCU Lock valve Fin stern
starboard Open Circuit
No current detected through the valve
when the valve is turned on.
-Check for open circuit
L2
45014.103.16
FCU Lock valve Fin stern
starboard Short Circuit
Current through valve is too high.
Trigger at 1.5A
-check for short circuit
L2
Page 4