11
Stabilizer Operation and User guide
version 5288-2 - 2018
SCU-1x
45000.100.21
FCU Tuning Fin bow port
Failed
Tuning sequence has failed. Trigger if fin
movement is less than 50 degrees.
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
L2
45000.101.21
FCU Tuning Fin bow
starboard Failed
Tuning sequence has failed. Trigger if fin
movement is less than 50 degrees.
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
L2
45000.102.21
FCU Tuning Fin stern port
Failed
Tuning sequence has failed. Trigger if fin
movement is less than 50 degrees.
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
L2
45000.103.21
FCU Tuning Fin stern
starboard Failed
Tuning sequence has failed. Trigger if fin
movement is less than 50 degrees.
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
L2
45001.100.21
FCU Encoder Fin bow port
Failed
Encoder fault
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
-Check if something is
blocking the actuators
-Check if all the hydraulics
mounted correctly to the
actuators.
-Check if a PHC-3 fault is
present.
L2
45001.100.22
FCU Encoder Fin bow port
Out off position
Encoder position is outside the end stop
position.
-Run the detect end stop
sequence.
-Check encoder belt and
pulleys.
-Consult Side-Power dealer
L2
45001.101.21
FCU Encoder Fin bow
starboard Failed
Encoder fault
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
-Check if something is
blocking the actuators
-Check if all the hydraulics
mounted correctly to the
actuators.
-Check if a PHC-3 fault is
present.
L2
45001.101.22
FCU Encoder Fin bow
starboard Out off position
Encoder position is outside the end stop
position.
-Run the detect end stop
sequence.
-Check encoder belt and
pulleys.
-Consult Side-Power dealer
L2
45001.102.21
FCU Encoder Fin stern port
Failed
Encoder fault
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
-Check if something is
blocking the actuators
-Check if all the hydraulics
mounted correctly to the
actuators.
-Check if a PHC-3 fault is
present.
L2
45001.102.22
FCU Encoder Fin stern port
Out off position
Encoder position is outside the end stop
position.
-Run the detect end stop
sequence.
-Check encoder belt and
pulleys.
-Consult Side-Power dealer
L2
45001.103.21
FCU Encoder Fin stern
starboard Failed
Encoder fault
-Run bleeding to get rid of air
in the hydraulic system
-Check encoder belt and
pulleys.
-Check if something is
blocking the actuators
-Check if all the hydraulics
mounted correctly to the
actuators.
-Check if a PHC-3 fault is
present.
L2
Page 2
Alarms and System monitoring