Operation and User guide
Stabilizer
Systems
US Patent US9527556
AU Patent AU2013335369
Patent pending: PCT/NO2013/050067
Document id:
5288
Revision: 2
Страница 1: ...Operation and User guide Stabilizer Systems US Patent US9527556 AU Patent AU2013335369 Patent pending PCT NO2013 050067 Document id 5288 Revision 2...
Страница 2: ...and User guide version 5288 2 2018 Contents Information and safety 3 Use Main Menu 5 Alarms and system monitoring 9 Service and Maintenance 15 Technical Specifications 19 Warrany Statement 20 Declara...
Страница 3: ...r assemblies penetrating through each side of the yachts hull and hydraulically pow ered with a Side Power compact Hydraulic System The system is electronically gyro controlled utilizing the Side Powe...
Страница 4: ...o the fins are left in a fixed position this can make the boat behave differently then expected at high speeds With the stabilizer system active it will ensure that the boats behaviour is predictable...
Страница 5: ...reen Touch arrow triangle on the right Green light is indicating GPS available Powerpack VFD enabled Powerpack VFD ready Red light is indicating not ready 1 2 Gain screen Possible to adjust the system...
Страница 6: ...3 Stabilizers are active in CRUISING mode Usually in use from 3 4 knots and up Note System change automatically between Cruising At Anchor when both is activated 2 4 Activate Stabilizers to AT ANCHOR...
Страница 7: ...ew alarm list 4 2 Alarm list shows current alarms with alarm description To acknowledge alarm s touch ACKNOWLEDGE ALARMS in the bottom of the screen 4 3 Touch the active alarm for more details and Cor...
Страница 8: ...IEW HISTORICAL ALARMS 5 1 Go to home page Scroll to System devices Touch System devices 5 2 Touch desired device s 5 3 Historical Alarms pop s up Touch Historical alarms 5 4 Historical Alarms is shown...
Страница 9: ...tank beware that the pumps will be destroyed if run dry and can then also cause other damage to the power source driving them If you have to run engines with pumps directly fitted disconnect mechanica...
Страница 10: ...ssure Check PHC 3 faults for more information L2 40004 0 210 PHC 3 DEVICE IN MANUAL MODE Trigger when the SCU try to startup PHC 3 and the PHC 3 is running in manual mode Stop running the PHC 3 in man...
Страница 11: ...der position is outside the end stop position Run the detect end stop sequence Check encoder belt and pulleys Consult Side Power dealer L2 45001 101 21 FCU Encoder Fin bow starboard Failed Encoder fau...
Страница 12: ...ted through the valve when the valve is turned on Check for open circuit L2 45006 102 51 FCU Proportional Valve 1 Fin stern port Current High Current through valve is too high Trigger at 3 75A check f...
Страница 13: ...Short Circuit Current through valve is too high Trigger at 1 5A check for short circuit L2 45013 101 13 FCU Float valve Fin bow starboard Open Circuit No current detected through the valve when the v...
Страница 14: ...stem wrong configured with thrusters parameter 2001 or 2101 10512 0 51 PHC DOUT LS DUMP Current High LS Dump valve current higher than 4 0A Check wires and connections for short circuit 10513 0 51 PHC...
Страница 15: ...the fin and the underside of the hull o Axial play should be checked by measuring the relative distance between the top of the axle shaft and hull plate By using a crow bar on the twin yoke moving an...
Страница 16: ...longer periods and either manually rotated every 3 months or started to ensure proper lubrication of the shafts and bearings on its shaft and bearings PREVENTATIVE MAINTENANCE SCHEDULE The maintenanc...
Страница 17: ...ic Hoses 1 W 8 Check Shaft Clearances 3 D 9 Replace Lower Shaft Seals 3 D 10 Replace Main Shaft Bearings 3 D 11 Inspect and replace Spherical Bear ings and Cylinder Pins if necessary NOT relevant for...
Страница 18: ...Tubes 1 W 7 Inspect Pump Drive Coupling 1 W 8 Inspect Motor and Frame Mounts 1 W 9 Test Hydraulic Oil Quality by means of taking sample 2 W 12 1st 10 Replace Return Filter Element 1 W 24 2nd 11 Repla...
Страница 19: ...ons Stabilizer Panel TP 43A Input voltage 8 31VDC Power consumption 3 5W Operating temperature 10 to 70 degrees C Storage temperature 30 to 80 degrees C IP rating front IP67 IP rating rear IP66 Humidi...
Страница 20: ...he purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Installation and Operation Manual have been comp...
Страница 21: ...accessories SCU Side Power Stabilizer Control System Stabilizer Control Unit FCU Side Power Stabilizer Control System Fin Control Unit TP 43 Panel Side Power Stabilizer Control System Stabilizer Main...
Страница 22: ...22 Stabilizer Operation and User guide version 5288 2 2018...
Страница 23: ...23 Stabilizer Operation and User guide version 5288 2 2018...
Страница 24: ...t was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product spe...