PHC-3 Alarm Descriptions
EN
MC_0117
Fault Code
Description
Cause
Action
10500.0.10
PHC Oil Level - Level Low
Hydraulic oil level is low
-Limit the use of thruster
-Inspect hydraulic oil level
-Check system for leaks and refi ll hydraulic oil
10500.0.13
PHC Oil Level - Open Circuit
Analog oil level sensor open circuit
-Sensor not connected or wire break.
-Verify sensor type in parameter 0201
-Disconnect sensor and measure that sensor resistance value is in
range 0-180ohm.
10501.0.11
PHC Oil Temp - Level High
Oil temperature higher than 75°C (167°F)
-Limit the use of thruster to prevent temperature to rise.
-Check if the cooling pump is running and there is cooling water fl ow.
-Inspect seawater fi lter
-Verify that cooling pump is enabled in parameter 0301
10501.0.13
PHC Oil Temp - Open Circuit
Analog oil temp sensor open circuit
-Sensor not connected or wire break.
- Disconnect sensor and measure that sensor resistance value is in
range 104ohm-147Kohm
-The wrong sensor is defi ned in parameter 0201
10501.0.16
PHC Oil Temp - Short Circuit
Analog oil temp input short circuit
-Input shorted to GND, check wiring/sensor
-Disconnect sensor and measure that sensor resistance value is in
range 104ohm-147Kohm
10502.0.13
PHC Stablizier Pressure - Open Circuit
Stabilizer pressure sensor open circuit
-Sensor not connected or wire break.
-System incorrectly confi gured with stabilizer, parameter 1001
-Replace sensor
10502.0.16
PHC Stablizier Pressure - Short Circuit
Stabilizer pressure sensor short circuit
-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor
10502.0.19
PHC Stablizier Pressure - Under Limit
Stabilizer pressure has dropped below 20bar.
-Check accumulator charge pressure
-Check PTO pressure (if PTO powered)
-Check system for oil leaks
10502.0.20
PHC Stablizier Pressure - Over Limit
Stabilizer pressure is higher than:
set point + 30bar running from PTO
or set point + 15bar running from AC motor
-Check PTO pressure setting
-Check accumulator charge pressure
10502.0.26
PHC Stablizier Pressure - VALUE MAX
Stabilizer pressure reached sensor max value.
-Check that the correct sensor is fi tted
-Check that sensor range parameter 1010 match the sensor
-Check PTO pressure setting
10502.0.200 PHC Stablizier Pressure - Timeout
Stabilizer pressure has not reached 50% of setpoint parame-
ter 1003 after 30sec.
-Check the pump feed shutoff valve.
-Check PTO pressure (if PTO powered)
-Check system for oil leaks
10503.0.13
PHC System Pressure - Open Circuit
System pressure sensor open circuit
-Sensor not connected or wire break.
-Verify system pressure, parameter 0104
10503.0.16
PHC System Pressure - Short Circuit
System pressure sensor short circuit
-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor
10504.0.13
PHC AI 1 - Open Circuit
Analog Input 1 (4-20mA) sensor open circuit
-Sensor not connected or wire break.
10504.0.16
PHC AI 1 - Short Circuit
Analog Input 1 (4-20mA) sensor short circuit
-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor
10505.0.13
PHC AI 2 - Open Circuit
Analog Input 2 (4-20mA) sensor open circuit
-Sensor not connected or wire break.
10505.0.16
PHC AI 2 - Short Circuit
Analog Input 2 (4-20mA) sensor short circuit
-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor
10508.0.13
PHC DOUT AC PUMP UNLOAD - Open Circuit
AC Pump Unload valve open circuit
-Check for open circuit, power consumption < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001
10508.0.51
PHC DOUT AC PUMP UNLOAD - Current High
AC Pump Unload valve current higher than 4.0A
-Check wires and connections for short circuit
10509.0.13
PHC DOUT ACCUMULATOR DUMP - Open
Circuit
Accumulator Dump valve open circuit
-Check for open circuit, power < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001
10509.0.51
PHC DOUT ACCUMULATOR DUMP - Current
High
Accumulator Dump valve current higher than 4.0A
-Check wires and connections for short circuit
10510.0.13
PHC DOUT STABILIZER - Open Circuit
Stabilizer valve open circuit
-Check for open circuit, power consumption < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001
10510.0.51
PHC DOUT STABILIZER - Current High
Stabilizer valve current higher than 4.0A
-Check wires and connections for short circuit
10511.0.13
PHC DOUT COOLING PUMP HYDRAULIC -
Open Circuit
Hydraulic Cooling Pump valve open circuit
-Check for open circuit, power consumption < 5.0 Watt
-Wrong cooling pump confi gured, parameter 0301
10511.0.51
PHC DOUT COOLING PUMP HYDRAULIC -
Current High
Hydraulic Cooling Pump valve current higher than 4.0A
-Check wires and connections for short circuit
10512.0.13
PHC DOUT LS DUMP - Open Circuit
LS-Dump valve open circuit
-Check for open circuit, power consumption < 5.0 Watt
-System wrong confi gured with thrusters, parameter 2001 or 2101
10512.0.51
PHC DOUT LS DUMP - Current High
LS-Dump valve current higher than 4.0A
-Check wires and connections for short circuit
10513.0.51
PHC DOUT PUMP #2 - Current High
Pump #2 valve current higher than 4.0A
-Check wires and connections for short circuit
10514.0.13
PHC DOUT 5 - Open Circuit
Digital Output 5 is confi gured as crossover and output is open
circuit
-Check for open circuit, power consumption < 5.0 Watt
-Output confi gured wrong, parameter 0505
10514.0.51
PHC DOUT 5 - Current High
Digital Output 5 current higher than 4.0A
-Check wires and connections for short circuit
10515.0.13
PHC DOUT 6 - Open Circuit
Digital Output 6 is confi gured as crossover and output is open
circuit
-Check for open circuit, power consumption < 5.0 Watt
-Output confi gured wrong, parameter 0506
10515.0.51
PHC DOUT 6 - Current High
Digital Output 6 current higher than 4.0A
-Check wires and connections for short circuit
10516.0.13
PHC DOUT 3 - Open Circuit
Digital Output 3 is confi gured as crossover and output is open
circuit
-Check for open circuit, power consumption < 5.0 Watt
-Output confi gured wrong, parameter 0503
10516.0.51
PHC DOUT 3 - Current High
Digital Output 3 current higher than 4.0A
-Check wires and connections for short circuit
12
6032
3
2019
-
SEP user manual
Содержание SH SERIES
Страница 18: ...MC_0037 Notes EN 18 6032 3 2019 SEP user manual ...
Страница 19: ...MC_0037 Notes EN 19 6032 3 2019 SEP user manual ...
Страница 20: ...MC_0037 Notes EN 20 6032 3 2019 SEP user manual ...
Страница 21: ...MC_0037 Notes EN 21 6032 3 2019 SEP user manual ...
Страница 22: ...MC_0037 Notes EN 22 6032 3 2019 SEP user manual ...