11
6032
3
2019
-
SEP user manual
Alarm Descriptions
EN
MC_0053
1. PPC520, PPC820, PPC800, PPC840
2. Buzzer is only activated when any device is sending thrust on the S-link bus.
"Err.
No."
Errors shown in display "Auto
Reset"
"Ext. buzzer
activation at
Alert Level"
Description
Action
19
Actuator Fault
2
(
²
)
, 3
Actuator not getting any power
"Check actuator connection or pow-
er to actuator. Reset alarm in alarm
menu on PJC 211/212/221/222 or
recycle power."
20
Pos.Sensor Fault
2
(
²
)
, 3
Retract position sensor fail
Check position sensor cables and
for sensor damage.
21
In Service Mode
Yes
2
(
²
)
, 3
"Retract controller in service mode. Switch
no. 4 is ON."
Check dipswitch setting on retract
control box.
22
High Oil Temp
Yes
1, 2
(
²
)
, 3
"Hydraulic oil temperature is higher than
75°C /167°F."
"Stop running and wait for tempera-
ture to drop.
Check if cooling pump is running."
23
Low Oil Level
1, 2
(
²
)
, 3
Hydraulic oil lewel is to low
Fill more hydraulic oil to the hydrau-
lic tank.
24
Warning Return Filter
Yes
2
(
²
)
, 3
Return fi lter element requiered
replacing.
25
Warning Pressure Filter
Yes
2
(
²
)
, 3
Pressure fi lter element requiered
replacing.
26
Warning High Speed
Yes
1, 2
(
²
)
, 3
"WARNING! High Speed.
Stabilizer not active!"
27
Stabilizer Fault
Yes
1, 2
(
²
)
, 3
Any Stabilizer alarm.
See stabilizer panel for more info.
28
AC Motor Overtemp
Yes
1, 2
(
²
)
, 3
"Hydraulic AC motor power pack over-
temp. Higher than
120°C/248°F."
Stop running and wait for tempera-
ture to drop.
29
AC Motor Sensor Fail
2
(
²
)
, 3
"Hydraulic AC motor power pack temp
sensor open curicuit"
Check sensor cables.
30
Temperature Warning
Yes
2
(
²
)
, 3
(
²
)
High temperature warning.
Warns that the motor temperature is
getting high.
31
Motor Overtemp
Yes
1, 2
(
²
)
, 3
High temperature Alarm.
See SAC manual for more details.
32
VFD Warning
Yes
2
(
²
)
, 3
There is an warning from VFD.
Check VFD for more details.
33
VFD Not Ready
Yes
2
(
²
)
, 3
The VFD is not ready.
Check VFD for more details.
34
VFD Fault
1, 2
(
²
)
, 3
VFD has an Alarm.
Check VFD for more details.
35
Warning Low Voltage
Yes
2
(
²
)
, 3
(
²
)
Low motor voltage warning when motor
is running.
12V thruster below 9.30V
24V thruster below 17.50V
36
Not Calibrated
Yes
2
(
²
)
, 3
Shaft Not Calibrated
See manual for how to calibrate.
37
VFD Com. Fault
2
(
²
)
, 3
No Modbus communication with VFD
Check VFD Modbus cables and
power.
38
Cooling Fan Fault
2
(
²
)
, 3
Cooling fan stopped running, or running
too slow
Device must be sent for service
39
Interlock
2
(
²
)
, 3
S-link communication between PPC and
retract controller are missing
-Check PPC or retract controller has
power.
-Check S-Link connections to PPC
and retract controller.
-Check if not PPC or SR150000/
SR61242 is wrongly setup as SRP or
SRVP/SRLP.
Содержание SH SERIES
Страница 18: ...MC_0037 Notes EN 18 6032 3 2019 SEP user manual ...
Страница 19: ...MC_0037 Notes EN 19 6032 3 2019 SEP user manual ...
Страница 20: ...MC_0037 Notes EN 20 6032 3 2019 SEP user manual ...
Страница 21: ...MC_0037 Notes EN 21 6032 3 2019 SEP user manual ...
Страница 22: ...MC_0037 Notes EN 22 6032 3 2019 SEP user manual ...