11
5693
2
2019
-
SE60/185 S2
MG_0024
Thuster
Motor
Ext. cable
4- or 5-lead
Y cable
4- or 5-lead
1
Timer
(Direction)
SIDE-POWER ‘on-off’
control panel
(ON)
2
3
blue
(STB)
grey
(POR
T)
red
yellow
black
Ext. cable
4- or 5-lead
Option: Automatic main switch. connects the battery to
the thruster. Operated from the control panel(s).
Requires 5-lead control cables.
MG_0031
After all electrical connections have been completed check with an ohm meter that there is no electrical connection between electro
motor body and positive terminal on the motor and between the electro motor body and the negative (A1) terminal on the motor. If you
feel unsure on how to perform this check, contact skilled personnel for guidance.
6 1265
5-LEAD
Y-CONNECTOR
6 1265
5-LEAD
Y-CONNECTOR
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
STERN
BOW
STERN
BOW
STERN
6 1278-xxM
5-LEAD
CONTROL CABLE
Switch
5A fuse
Switch
5A fuse
Common negative
10A fuse
+
-
+
-
IMPORTANT!
Common negatvie MUST be wired when using control panel 8940 and 8909C
if separate battery banks are installed. (Bow and Stern thtrusters combined)
6 1274
4-LEAD
Y-CONNECTOR
STERN
BOW
STERN
BOW
STERN
xA fuse
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1274
4-LEAD
Y-CONNECTOR
xA fuse
Common negative
10A fuse
+
+
-
-
IMPORTANT!
Common negatvie MUST be wired when using control panel 8940 and 8909C
if separate battery banks are installed. (Bow and Stern thtrusters combined)
With Automatic Main Switch:
With Manual Main Switch: