10
5693
2
2019
-
SE60/185 S2
Control Panel Cable Installation
EN
• All standard Sidepower control panels can be used in any combination as well as any two-way switching device when installed with an ON/OFF switch
that breaks control power to this switch.
• As many control panels can be installed using optional Y-connectors or T-connectors if installing an S-link system.
(NB: If two or more control panels
are operated at the same time in opposite directions, the electronic control box will stop the thruster until it receives a single signal or thrust
in one direction.)
• When using original Sidepower equipment it is entirely “plug & go” and no additional confi guration setup is required.
• All controls must have spring load for automatic return to neutral position.
(NB: If the drive direction of the thruster is running opposite to the control panel, the electronic control box rotated 180 in its clip to swap the
blue and grey wire on the thruster solenoid.)
Pin confi guration of 4 pole AMP contact:
Pin1: BLACK = Ground
Pin2: BLUE = Engages thruster SB solenoid
Pin3: GREY = Engages thruster Port solenoid
Pin4: RED = Positive voltage for the control panel
MC_0041
!
Please refer to the graphic for special considerations relating to your model
!
MG_0024
Thuster
Motor
Ext. cable
4- or 5-lead
Y cable
4- or 5-lead
1
Timer
(Direction)
SIDE-POWER ‘on-off’
control panel
(ON)
2
3
blue
(STB)
grey
(POR
T)
red
yellow
black
Ext. cable
4- or 5-lead
Option: Automatic main switch. connects the battery to
the thruster. Operated from the control panel(s).
Requires 5-lead control cables.
MG_0031
After all electrical connections have been completed check with an ohm meter that there is no electrical connection between electro
motor body and positive terminal on the motor and between the electro motor body and the negative (A1) terminal on the motor. If you
feel unsure on how to perform this check, contact skilled personnel for guidance.
6 1265
5-LEAD
Y-CONNECTOR
6 1265
5-LEAD
Y-CONNECTOR
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
STERN
BOW
STERN
BOW
STERN
6 1278-xxM
5-LEAD
CONTROL CABLE
Switch
5A fuse
Switch
5A fuse
Common negative
10A fuse
+
-
+
-
IMPORTANT!
Common negatvie MUST be wired when using control panel 8940 and 8909C
if separate battery banks are installed. (Bow and Stern thtrusters combined)
6 1274
4-LEAD
Y-CONNECTOR
STERN
BOW
STERN
BOW
STERN
xA fuse
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1274
4-LEAD
Y-CONNECTOR
xA fuse
Common negative
10A fuse
+
+
-
-
IMPORTANT!
Common negatvie MUST be wired when using control panel 8940 and 8909C
if separate battery banks are installed. (Bow and Stern thtrusters combined)
With Automatic Main Switch:
With Manual Main Switch: