5
INSTALLATION
5
Align the sensor
horizontally
so that the laser beam strikes the vertical line of the cross-
hair of the other laser adjustment unit
see Fig. “Laser adjustment unit”, page 21
). To do
this, tap very lightly against the front lower edge of the sensor enclosure with a rubber
hammer (
see Fig. “Horizontal sensor alignment”, page 22
).
Fig. 12: Horizontal sensor alignment
6
Tighten both retaining screws of the sensor with 45 Nm, use a torque wrench as
necessary.
7
Slightly loosen the angle bracket screws.
8
Align the sensor
vertically
so that the laser beam strikes the
horizontal line
of the cross
hair of the other laser adjustment unit (
see Fig. “Laser adjustment unit”, page 21
). To do
this, tap very lightly against the front lower edge of the angle bracket with a rubber
hammer (
see Fig. “Vertical sensor alignment”, page 22
).
Fig. 13: Vertical sensor alignment
9
Tighten the angle bracket, use a torque wrench as necessary.
10
Check again whether the laser beam strikes the crosshair and correct as necessary.
11
Switch the laser adjustment unit off.
1
Retaining screws
2
Angle bracket screws