5
Mounting
5.1
Mounting instructions
•
Observe the technical data.
•
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
•
The mounting site has to be designed for the weight of the device.
•
When using multiple devices, observe the mounting distance,
5.2
Mounting distances
Table 3: Mounting distances
Device type
Parallel
Opposite
UC12-11xx
> 250 mm
> 1300 mm
UC12-12xx
> 250 mm
> 1400 mm
5.3
Aligning the device
≤ ± 3°
≥ ± 3°
1
2
Figure 4: Aligning the device for smooth and rough surfaces
1
Smooth surface: Angle ≤ 90° ± 3° between the sensor axis and object surface
2
Rough surface: Angle ≥ 90° ± 3° between the sensor axis and object surface
MOUNTING
5
8010984/1BNB/2022-05-12 | SICK
O P E R A T I N G I N S T R U C T I O N S | UC12
15
Subject to change without notice