Table 42: Filter selection
Filters
Configurable
Frequency range
Areas of application
Butterworth
0.1 Hz to 25 Hz
Static inclination measurement with high damping against
vibrations
Critically
damped
0.1 Hz to 8 Hz
Inclination measurement for applications subject to specific
dynamics / without overshoot in the event of changes in
angle combined with good damping
The digital filter is selected via entry 3000.01h. The limit frequency is set via object
3000.02h. Values from 100 (= 0.1 Hz) to 25,000/8,000 (= 25 Hz/8 Hz) are permitted.
0
1
2
3
4
5
6
7
8
9
10
0
5
10
15
Step response 8th order filter
Time [s]
Step
Butterworth, f
c
= 2 Hz
Butterworth, f
c
= 0.5 Hz
critically damped, f
c
= 2 Hz
critically damped, f
c
= 0.5 Hz
T
ilt [°]
Figure 19: Pulse response of both filters
9
CANOPEN INTERFACE
38
OPERATING INSTRUCTIONS
| TMS/TMM88, TMS/TMM61
8019054/14IT/2019-06-27
| SICK