7.2
Mounting instructions
Figure 6: Mounting instructions
The TMS/TMM22 inclination sensors are fastened with 3 M3 screws. A tightening
torque of 1.4 Nm must not be exceeded. Make sure that the mounting surface is as flat
as possible to avoid mechanical stresses and to ensure good measurement results.
MOUNTING
7
8026576/1EF6/2021-12-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | TMS/TMM22
11