5
COMMISSIONING AND CONFIGURATION
24
SAFETY-RELATED 2D LIDAR SENSOR | TIM361S
8022483/108R/2018-07-09 | SICK
Subject to change without notice
Particle filter
Default:
Particle filter is "deactivated"
The particle filter should be deactivated, since otherwise objects that appear
sporadically and for a short time will not be detected and/or filtered out. Similarly, the
particle filter also delays the functioning of the switching outputs.
Teach button
Default:
TeachIn (SOPAS) is deactivated ("TeachIn disabled")
The TeachIn function (including via switching input) is deactivated in order to prevent
unintentional configuration.
Duration time for the outputs
Default:
Maximum (Duration Time) on the outputs
The sensor automatically releases its protective field outputs when no more objects are
detected. The maximum output delay (duration time) therefore prevents immediate
restart.
Important!
Continuous restart interlock with reset function must be implemented by
the user in the application.