1
Bottom flat seal
6.
Loosen the glass fiber filter element from the filter handle by opening the spiral
thread.
1
O-ring
2
Glass fiber filter element
3
Rotary handle
7.
Insert new bottom flat seal.
8.
Renew the O-ring in the filter cover.
9.
Fit new or cleaned glass fiber filter element on the filter cover. Tighten the spiral
thread.
If one side of the filter element has a groove: The groove must point in the direc‐
tion of the filter cover.
10. Replace the filter cover.
1
Rotary handle
2
Pressure disk
3
Mounting bracket
11. Swing back the mounting bracket. Make sure that the pressure disk is behind the
mounting bracket.
5
MAINTENANCE
28
O P E R A T I N G I N S T R U C T I O N S | SFU
8023849/14SF/V1-1/2019-07 | SICK