Operating Instructions
Chapter
5
RFH620 Interrogator
Installation
8013105/0000/2009-05-12
©
SICK AG · Division Auto Ident · Germany · All rights reserved
31
5
Installation
5.1
Overview of installation sequence
This chapter describes the installation sequences for the interrogator and its external com-
ponents.
The typical installation sequences are listed below:
•
Select the installation location for the interrogator
•
Install the interrogator
•
Install connection module CDB620 or CDM420
•
Connect the interrogator to connection module CDB620 or CDM420
•
Install the reading pulse sensor for reading pulse triggering
Important
Do not open the interrogator's housing. If the device is opened, the SICK AG warranty shall
not apply.
5.2
Installation preparations
In general, the following requirements should be observe for the installation:
•
Typical space requirement: application-specific
•
More stable installation bracket with sufficient load capacity and measurements suited
for the interrogator (see
chapter 10.2 Interrogator´s dimensional drawings RFH620.,
)
•
Shock absorbent and vibration free attachment
The following tools and resources are required for the installation:
•
Two M6 bolts:
The bolts serve for the installation of fastening bracket no. 2048551 to the base.
The bolt length depends on the wall thickness of the base.
•
Tool
•
Tape measure (up to 1 m (3.28 ft))
5.2.1
Components to be installed
For the installation, the following must be handy:
•
Interrogator RFH620
5.2.2
Accessories
The following accessories are not included in the delivery of the interrogator. If required,
they have to be ordered separately and placed ready for installation:
•
Mounting device, see next chapter
•
Connection module CDB620 or CDM420
•
Reading pulse sensor for external reading pulse triggering, e. g., photoelectric reflex
switch/photoelectric proximity switch