COMMISSIONING AND CONFIGURATION
7
7.2.2
SOPAS ET default settings
Table 15: SOPAS ET default settings
7.3
Establishing communication with the NAV245
Important
To communicate via TCP/IP, the TCP/IP protocol on the PC must be active.
When connecting a PC/host, please adhere to the following order:
1
Switch on the PC.
2
Connect the PC to the NAV245 with a data cable.
3
Switch on the supply voltage to the NAV245.
The NAV245 performs a self-test and initializes itself.
7.3.1
Connecting data interfaces
▸
Connect the PC to the NAV245 with an Ethernet cable (see “NAV245: Ethernet
connection with the Ethernet cable” on page 60)
or
▸
Connect the PC (serial interface) to the NAV245
7.3.2
Configuring the Ethernet connection
The factory setting for the Ethernet interface of the NAV245 is:
– IP address: 192.168.0.1
– Subnet mask: 255.255.255.0
– TCP/IP port for SOPAS ET: 2111
Using the SOPAS tool, there are several different ways to find the NAV245. You can select
these in the search settings:
– Search by device family (recommended)
– Search by communication interface
When searching by communication interface, the scanner can be found with an automatic
IP address search or the IP address can be configured manually.
You can find additional information on operation via the help menu -> SOPAS handbook.
Parameter
Value
User interface language
English (you must restart the software after making any changes)
Units of length
Metric
User group (operating level) Machine operator
Download parameters to
the NAV245
Immediately after a change, temporarily in the RAM of the NAV245
Upload parameters from
the NAV245
Automatically after being switched to online
Window arrangement
3 (project tree, help, working area)
Serial communication
57,600 Bd, 8 data bits, no parity, 1 stop bit