O P E R A T I N G I N S T R U C T I O N S | NAV245
Subject to change without notice
PRODUCT DESCRIPTION
3
3.8.8
Detection mode
Various filter settings can be adjusted with the detection mode. It is possible to limit the
detection zone or to change the sensitivity.
The detection mode evaluates the measurement data of the surrounding contour according
to individual landmarks with the help of algorithms and therefore improves the evaluation of
the measured values. If properties are determined which could influence the measurement
accuracy, the affected landmarks are filtered out.
You can set the sensitivity using the parameter NLMDDetectionMode.
You can set the detection mode via SOPAS landmark configuration:
Fig. 24: Setting detection mode
Parameter
Meaning
Accuracy (default setting)
Only landmarks with a verified high level of accuracy.
– PartlyCovered filter threshold is 200 mm.
Standard
More landmarks are available but potentially with a
larger measurement error.
– PartlyCovered filter threshold is 500 mm.
– ReflectiveAlignment filter is deactivated.
Availability
No landmark filtering at surrounding contour.
– PartlyCovered filter is deactivated.
– ReflectiveAlignment filter is deactivated.