5
Mounting
5.1
Mounting instructions
•
Observe the technical data.
•
Protect the sensor from direct sunlight.
•
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
•
The mounting site has to be designed for the weight of the device.
•
Protect the device from moisture, contamination, and damage.
•
Make sure that the status indicator is clearly visible.
•
Do not install the device at a location that can be easily accessed by unauthorized
persons.
•
The front screen of the device must not be subjected to strong forces (> 1 joule),
such as impact, for example.
•
The device must be protected from impacts, vibrations, the effect of shocks, and
other mechanical and chemical influences.
5.2
Mounting device
1.
Attach the mounting bracket at the desired position. Mounting brackets are avail‐
able as accessories,
2.
Make the electrical connection. Attach and tighten a voltage-free cable,
necting the device electrically", page 25
3.
Mount the device at the bracket using the fixing holes provided (
). Always fasten the device with 4 screws, tightening torque: 5.2 Nm.
4.
Switch on the supply voltage.
✓
Following successful initialization, the green status LEDs light up. The device is
ready for use.
5.3
Mounting multiple devices
NOTICE
Risk of interference from other devices!
Radiation sources with a wavelength of 870 nm can cause interference if they affect
the device directly.
The device has been designed to minimize the probability of mutual interference with
devices of the same type. To rule out even the slightest effects on the measurement
accuracy, the devices should be arranged such the laser beams are not received by
another device.
Figure 12: Arrangement for 2 devices
MOUNTING
5
8022069/114M/2019-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | MRS6000
23