1 1 1 1 1 … 1
2 2 2 2 2 … 2
3 3 3 3 3 … 3
4 4 4 4 4 … 4
5 5 5 5 5 … 5
6 6 6 6 6 … 6
7 7 7 7 7 … 7
… …
1
3
2
5 4
6
7
Figure 10: MRS6000 light spot and measuring points
1
Light spot width / measuring point width (56.6 mm at distance of 25 m)
2
Distance between 2 measuring points (approx. 1 mm at distance of 25 m)
3
Minimum object size (56.7 mm at distance of 25 m)
4
Vertical distance between 2 measuring points (272 mm at distance of 25 m)
5
Light spot height (1641 mm at distance of 25 m)
6
Vertical detection range = 4x light spot height (6401 mm at distance of 25 m)
7
Horizontal detection range (923 measuring points above 120°)
3.5.6
Multi-echo analysis
The distance between the device and an object is calculated via the time-of-flight of the
emitted pulse. The MRS6000 can evaluate up to four echo signals for each measuring
beam to deliver reliable measurement results, even under adverse ambient conditions.
PRODUCT DESCRIPTION
3
8022069/114M/2019-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | MRS6000
17
Subject to change without notice