Telegram part
Description
Variable Length Values CoLa A (ASCII)
Values CoLa B (binary)
Output
channel
(16 bit)
Content
Defines the content of
the output channel
Unit of radial distance
values (DIST) is mm
String
5
DIST1: Distance values
RSSI1: Energy values in
digit
REFL1: Calibrated energy
values in %
ANGL: Angle Offset values
44 49 53 54 31
52 53 53 49 31
52 45 46 4C 31
41 4E 47 4C
Scale factor
Scale factor or factor of
the measurement val‐
ues
Real
as float
accord‐
ing to
IEEE75
4
4
Factor x 0.1: 3DCCCCDh
(DIST1)
Factor × 1: 3F800000h
(RSSI1)
Factor × 1: 3F800000h
(REFL1)
Factor × 1: 3F800000h
(ANGL)
3D CC CC CD
3F 80 00 00
3F 80 00 00
3F 80 00 00
Scale factor
offset
Sets starting point of
measurement
Real
as float
accord‐
ing to
IEEE75
4
4
DIST1: 00000000h
RSSI1: 00000000h
REFL1: 00000000h
ANGL: C7000000h
(-32768)
00 00 00 00
00 00 00 00
00 00 00 00
C7 00 00 00
Start angle
[1/10000°]
Uint_32 4
+550000d… +1250000d
(86470h … 1312D0h)
00 08 64 70 …
00 13 12 D0
Size of single
angular step
Output format in
degree: 1/10000°
Uint_16 2
0.0833°: +833 (341h)
0.0833°: 03 41
Amount of
data
Defines the number of
items on measured out‐
put
Uint_16 2
0000h … FFFFh
00 00 … FF FF
Data_1
Data_n
Data stream starting
Data_1 to Data_n
Uint_16 2
0000h…C4Eh (DIST1)
0000h…FFFFh (RSSI1)
0000h…FFFFh (REFL1)
0000h…FFFFh (ANGL)
00 00 … 0C 4E
00 00 … FF FF
00 00 … FF FF
00 00 … FF FF
Amount of 8 bit chan‐
nels
Amount of 8 bit chan‐
nels, giving out the
measured data
Enum_1
6
2
Output channels: 0
Output channels: 00
Position
Output of position data Enum_1
6
2
No position data: 0
Position data: 1
No position data: 00 00
Position data: 00 01
ANNEX
12
8023198//2018-06-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | LMS4000
55