Filters
Edge filter, median filter, average filter
1
Typical value in the following ambient conditions: measuring range and remission as quoted (otherwise
full range), scan range 60° … 120°, ambient temperature 18 °C … 28 °C, ambient light ≤ 2,000 lux. The
actual measured values might deviate from the quoted value depending on the application setup.
10.3
Interfaces
Ethernet – function
TCP/IP
UDP/IP
Measurement data output (distance, angle, RSSI)
Ethernet – data transmis‐
sion rate
100/1,000 Mbit/s, full duplex, half duplex
Switching inputs
2 (2 x I/O)
Voltage 24 V DC, max. 50 kHz
Encoder inputs
2 (phase A, phase B), max. 50 kHz
Switching outputs
3 (1 x OUT, 2 x I/O)
max. 100 mA per output
Synchronization input/
output
1 (master/slave)
Optical indicators
4 LEDs
Configuration software
SOPAS ET
Telegram language
CoLa ASCII
CoLa binary
10.4
Mechanics/electronics
Electrical connection
1 x M12, 5-pin male connector (power + I/O + sync)
1 x M12, 8-pin female connector (Ethernet)
1 x M12, 5-pin female connector (e I/O)
Supply voltage
24 V DC ± 25%
Power consumption
≤
16 W (typical, at 24 V DC)
≤
29 W (start-up current)
26 W (max. continuous, all outputs loaded)
Output current
≤
100 mA per output
Housing
Aluminum die cast
Front screen material
Float glass
Housing color
Light blue (RAL 5012)
Enclosure rating
IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class
III (IEC 61140:2016-01)
Electrical safety
IEC 61010-1:2011
Weight
LMS4x1x: 2.4 kg
LMS4x2x: 3.7 kg
Dimensions (L x W x H)
LMS4x1x: 192 mm x 130 mm x 107 mm
LMS4x2x: 397 mm x 370 mm x 107 mm
10
TECHNICAL DATA
48
O P E R A T I N G I N S T R U C T I O N S | LMS4000
8023198//2018-06-18 | SICK
Subject to change without notice