10
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
10.1
Features
Version
Short range
Application
Indoor
Reading window/laser out‐
put aperture
On the front
Light source/laser diode
Visible light
(wavelength 660 nm; LMS4x11: max. output power 20 mW, aver‐
age power 10 mW; LMS4x21: max. output power 27 mW, average
power 13.5 mW)
Laser class
2 (IEC 60825-1:2014&2007)
Spot size/laser spread
4 x 3 mm, typical (front screen)
2.5 x 2 mm (3 m distance)
Aperture angle
70°
Scan frequency
600 Hz
Angular resolution
1/12° (0.0833°)
Operating range
0,7 m ... 3 m
Scanning range
3 m (2% remission)
3 m (10% remission)
Number of devices for
motor synchronization
Virtually unlimited, length of sync cable max. 20 m
10
TECHNICAL DATA
46
O P E R A T I N G I N S T R U C T I O N S | LMS4000
8023198//2018-06-18 | SICK
Subject to change without notice