6.
Use the plus or minus pushbutton to select the direction in which the segment
display points.
THR
PRO
TCH
PWR
Q
7.
Press the SET pushbutton.
6.8
Other indicators and functions
Control panel locked
THR
PRO
TCH
PWR
Q
If the device is undergoing an internal process (e.g., reading or storing parameter sets
or teaching in via IO-Link), the control panel is locked and the device shows “bSY” on
the segment display.
Short-circuit and overcurrent detection
THR
PRO
TCH
PWR
Q
In the event of a short-circuit, Err appears on the display and the Q LED flashes.
Live measured value (run mode)
In run mode, the device displays the remission value currently being measured as a
digit.
THR
PRO
TCH
PWR
Q
Table 9: Remission value indicator
Value
Remission value
0
No remission
400
White
999
Maximum remission, with glossy material
Display standby
NOTE
Control panel standby mode is not activated while an error message is displayed.
If no settings are made on the device for 5 minutes, standby mode is activated to save
electricity. The settings made, but not confirmed, are not adopted.
To quit standby mode, one of the operating keys must be pushed.
OPERATION
6
8020706.1E9P/2022-04-26 | SICK
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime
31