û
ü
Figure 10: KTX Prime light emission long housing side
1.
The adjustment quality is automatically shown in the display as mounting feed‐
back during the first device initialization. To do so, the device must be brought
within the nominal sensing distance manually, ideally on light material (see data
sheet). Pay attention to the figure during alignment. After adjustment, quit the
process with any pushbutton.
2.
Install the device via the fixing hole so that the light spot enters the mark longitudi‐
nally and the test object has the least possible vertical and horizontal movement.
Note the sensing distance while doing so.
3.
Compensate for the vertical and horizontal movement of the test object by marks
of suitable lengths.
4.
Ensure that any device movement does not affect the sensing distance.
Mounting feedback
NOTE
Assembly feedback (AdJ) is only available for standard variants with a sensing distance
of 13 mm and 25 mm.
Table 1: Mounting feedback indicator
THR
PRO
TCH
PWR
Q
Sensing distance set too close or too far away.
THR
PRO
TCH
PWR
Q
Sensing distance set within the detection range, but not at
the optimum level.
THR
PRO
TCH
PWR
Q
Nominal sensing distance set.
To secure a stable detection when having high gloss material a tilt angle of 10°-15°
might be necessary.
4
MOUNTING
16
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime
8020706.1E9P/2022-04-26 | SICK