Type
ICD880-4515x02x
ICD890-4434x02x
ICD890-4434x01x
ICD890-4523x01x
I/O (depends on vari‐
ant)
Variant A connection mask: not available
Variant B connection mask:
•
Function: supply voltage, trigger, encoder, RS-232 data interface, 3 digital outputs
•
Maximum length of cable: 10 m
•
Maximum encoder switching frequency: 30 kHz
•
Maximum switching frequency for trigger: 30 kHz
•
Maximum switching frequency for digital output: 1 kHz
•
Total output currents (supply voltage, digital outputs): max 1.5 A (internal electronic fuse)
•
Maximum current for digital output: 0.4 A
•
Maximum baud rate for RS-232: 115.2 kBd (depends on cable)
Optical indicators
3 status LEDs (device status indicators)
3 double LEDs (Ethernet status indicators)
Configuration software
SOPAS ET configuration software (workflow parameterization, installation wizard, diagnostic tools,
status information)
Storage media
2)
1 2.5 inch SSD (image and data logging)
1 microSD memory card (configuration data back-up)
1)
Data interface only for temporary use (service).
2)
Optional, not included with delivery.
11.5
Ambient data
Type
ICD880-4515x02x
ICD890-4434x02x
ICD890-4434x01x
ICD890-4523x01x
Electromagnetic com‐
patibility (EMC)
Interference: IEC 61000-6-4:2018
Immunity: EN IEC 61000-6-2:2019 (Industrial Environment)
Vibration resistance
IEC 60068-2-6:2007-12
Shock resistance
IEC 60068-2-27:2008-02
Ambient operating tem‐
perature
–10 °C ... +50 °C
Storage temperature
–20 °C ... +70 C
Permissible relative
humidity
Max. 95 %, non-condensing
Ambient light immunity 2,000 lx on code
1)
With connected, functional fan.
11.6
Dimensional drawing
.
TECHNICAL DATA
11
8023775/1A4I/2020-12-01 | SICK
T E C H N I C A L I N F O R M A T I O N | Camera ICD880/890 Generation 4
39