11
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
•
Please note: This documentation may contain further technical data.
11.1
Features
ICD880-4515x02x
ICD890-4434x02x
ICD890-4434x01x
ICD890-4523x01x
Function
line camera with integrated 1D/2D code decoder, image output and additional optional 2D vision
functions
Focus
Dynamic focus control or constant focus
Sensor
CMOS line sensor
Type: High resolution
CMOS line sensor
Type: Standard resolu‐
tion
CMOS line sensor
Type: Standard resolu‐
tion
CMOS line sensor
Type: High resolution
Processor
Standard performance
Standard performance
High performance
High performance
Line frequency (scan‐
ning rate)
Max. 43 kHz
Max. 50 kHz
Max. 50 kHz
Max. 43 kHz
Code resolution
≥
0.1 mm
Working range
850 mm … 1,500 mm
1
)
1,550 mm … 3,600 mm
1)
1,550 mm ... 3,600 mm
1)
1,550 mm ... 3,900 mm
1)
Field of view
Conveyor width
1,000 mm at 220 dpi
resolution
Conveyor width
800 mm at 277 dpi
resolution
Conveyor width
1,200 mm at 170 dpi
resolution
Conveyor width
1,035 mm at 200 dpi
resolution
Conveyor width
1,200 mm at 170 dpi
resolution
Conveyor width
1,035 mm at 200 dpi
resolution
Conveyor width
1,800 mm at 170 dpi
resolution
Conveyor width
1,560 mm at 200 dpi
resolution
Operating mode
Forward, Backward, Start/Stop
Lens
Integrated
Focal length: 80 mm
Integrated
Focal length: 95 mm
Integrated
Focal length: 95 mm
Integrated
Focal length: 120 mm
2D Vision functional‐
ity
2)
•
Extended analysis of code quality
•
empty tote detection
•
hazardous material detection
•
object classification
•
2D dimensioning (image-based calculation of object dimensions)
1)
Relative to the device reference point,
see "Field of view diagrams", page 40
2)
For further 2D Vision functions, contact SICK Sales. To find your agency, see the final page of this document.
11
TECHNICAL DATA
36
T E C H N I C A L I N F O R M A T I O N | Camera ICD880/890 Generation 4
8023775/1A4I/2020-12-01 | SICK
Subject to change without notice