11.3
Performance
Type
ICD880-4515x02x
ICD890-4434x02x
ICD890-4434x01x
ICD890-4523x01x
Readable code struc‐
tures
1D, 2D, Stacked, OCR, OCV
1D code types (bar
code types)
GS1-128 / EAN 128, UPC / GTIN / EAN, 2/5 Interleaved, Pharmacode, GS1 DataBar, Code 39, Code
128, Codabar, Code 32, Code 93, USPS (Postnet, Planet, USPS4SCB), Australia Post, Dutch KIX
Post, Royal Mail, Swedish Post
2D code types
Data Matrix ECC200, GS1 Data Matrix, MaxiCode, QR code, Aztek
Stacked code types
PDF417
Mounting bracket
Max. 75°
1)
Conveyor speed
Max. 4.5 m/s
1)
Minimum object dis‐
tance
≥ 50 mm
Number of objects per
second
≤ 10
Image output formats
JPEG, TIFF, BMP, thumbnail, up to 5 FTP clients
1)
Depending on the activated functionality.
11.4
Interfaces
Type
ICD880-4515x02x
ICD890-4434x02x
ICD890-4434x01x
ICD890-4523x01x
USB
1)
1 USB 2.0 (service)
Ethernet GBit
3 Ethernet GBit
Ethernet 2 and 3 are connected via a switch
Function: data output (read result), image transmission, and configuration with SOPAS ET
Data transmission rate: 1 GBit/s, full duplex
Protocols: TCP/IP, FTP (real time image output)
CAN
1 CAN IN, 1 CAN OUT
Protocol: CSN (SICK CAN Sensor Network)
Function: data output (read result)
Data transmission rate: 20 kBit/s ... 500 kBit/s
Bus length depends on data transmission rate and length of cable,
see "Wiring the CAN interface",
Light (depends on vari‐
ant)
Variant A connection mask:
•
1 Light 1, 1 Light 2
•
Light 1 function: communication with the illumination unit
•
Light 2 function: no function
Variant B connection mask:
•
1 Light 1
•
Function: communication with the illumination unit
FAN (depends on vari‐
ant)
Variant A connection mask:
•
1 FAN
•
Function: voltage supply and regulation of the device fan
•
I
Max
= 0.5 A
Variant B connection mask: not available, integrated fan connection available in the device
11
TECHNICAL DATA
38
T E C H N I C A L I N F O R M A T I O N | Camera ICD880/890 Generation 4
8023775/1A4I/2020-12-01 | SICK
Subject to change without notice