2
Safety information
2.1
Intended use
The GLS621 is used for automatic localization of automatic guided vehicles (AGVs) in
warehouses, logistics and distribution. The device detects and decodes 2D codes which
are attached in the form of a grid on the floor. Using the data provided by the device,
the AGV is localized and repositioned by a higher-level controller (e.g. PLC). The device
supports 4Dpro connectivity.
The device is primarily designed for use in industrial and logistics areas. The device
meets the applicable requirements for industrial robustness, interfaces and data proc‐
essing.
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.1.1
Conditions for specified enclosure rating
To ensure compliance with the specified enclosure rating of the device during opera‐
tion, the following requirements must be met: If these requirements are not met, the
device does not fulfill any specified enclosure rating.
•
The cables plugged into the electrical connections must be screwed tight.
•
Any electrical connections that are not being used must be sealed with a tightly-
fastened protective cap (as in the delivery condition).
•
The foldable cover must be flush with the device and screwed tight.
2.1.2
Cover on the device
NOTICE
Risk of product damage if cover is open!
In open state, the device does not conform to a specified enclosure rating.
If necessary, only operate the device for a short time with an open cover for the
activities listed in the following: During this time, protect the device against moisture
and dust.
Briefly open the cover for the following activities:
•
Inserting or removing the optional memory card
•
Temporary use of the USB interface as a service interface
For further warranty provisions, see the General Terms and Conditions of SICK AG, e.g.,
on the delivery note of the device.
2.2
Improper use
Any use outside of the stated areas, in particular use outside of the technical specifica‐
tions and the requirements for intended use, will be deemed to be incorrect use.
•
The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.
•
The device must not be used in explosion-hazardous areas, in corrosive environ‐
ments or under extreme environmental conditions.
•
The device must not be operated in the temperature range below 0 °C.
•
Any use of accessories not specifically approved by SICK AG is at your own risk.
2
SAFETY INFORMATION
8
O P E R A T I N G I N S T R U C T I O N S | GLS621
8024289/1E1C/2022-09-09 | SICK
Subject to change without notice