3.
Reconnect the connecting cables of the replacement device (
4.
Switch on the supply voltage for the replacement device.
✓
The device starts with its last permanently saved parameter set. In the case of
devices that have not been used before, this corresponds to the factory default
setting.
✓
The device searches for external storage media with a valid parameter set.
Depending on the success of the search, the replacement device proceeds as
follows:
°
When the replacement device detects an external storage medium, the
replacement device automatically transfers the configuration data to the
permanent device memory.
°
If the replacement device does not detect any external storage media, the
replacement device will start with its last permanently stored parameter set.
In the case of devices that have not been used before, this corresponds to
the factory default setting.
5.
Establish a connection with the replacement device using the SOPAS ET configura‐
tion software.
6.
Optional: transfer the configuration data of the device to be replaced by download‐
ing to the replacement device and permanently store this data in the device.