Product Description
DUSTHUNTER T · Operating Instructions · 8012428 V2.2 · © SICK AG
31
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
2.3.2
Device configuration
The device components required for a measuring system depend on the respective
application conditions. The following Table should serve to assist you in your selection.
Sender/receiver unit, reflector, flange with tube (standard components)
Voltage and purge air supply
Type DUST-
HUNTER
Active
measuring
path
Sender/receiver
unit
Reflector
Cable for reflec-
tor connection
Type MCU
Flange with tube
T50
0.5 ... 2.5 m
DHT-T00
DHT-R50
-
MCU-
xxON00000NNE
Flange with tube
k100
1x each for sender/
receiver unit and
reflector
2 ... 5 m
DHT-R51
4 ... 8 m
DHT-R52
T100
0.5 ... 2.5 m
DHT-T10
DHT-R00
-
MCU-
xxOD01000NNNE
2 ... 5 m
DHT-R01
4 ... 12 m
DHT-R02
10 ... 50 m
DHT-R13
T200
0.5 ... 2.5 m
DHT-T21
DHT-R10
x
MCU-
xxOD01000NNNE
2 ... 5 m
DHT-R11
4 ... 12 m
DHT-R12
10 ... 50 m
DHT-R13
Internal duct pressure
Connection and supply components
Purge air
Voltage
up to +2 hPa
MCU-P + purge air hose DN 40 (
> +2 hPa bis +30 hPa
Optional external purge air unit
MCU-N
We recommend using the optional external purge air unit when the control unit
is > 3 m away from the sender/receiver unit and/or reflector.