TROUBLESHOOTING 

- 485 & RTS

Troubleshooting - 485

For 485

Problem

Possible Cause

Action to Take

Drapes won’t 

operate.

Motor is not powered.

 

Please check AC connection, verify motor is plugged .

Incorrect or poor cable 

termination.

 Check the wire pinouts and termination. Look for broken, loose, 

or damaged wires. Reterminate if necessary.

 SIFI is not powered.

To verify the si.fi is powered look for a green LED flashing on the 

board, this light will either be steady on or flashing.  If no light 

is visible make sure power is available via the PoE injector or 

check the power of your PoE switch.

SIFI is not on the local 

network.

Use the service keypad (if available) to validate the 485 network 

and motors are operating properly before troubleshooting SI.FI 

network problems. Check that the SIFI is communicating on 

the local network. Ping the device via the windows command 

prompt, or make sure the device shows up in the network tab of 

the Windows File Explorer.

 

Remote button presses 

are too short.

 

 

When operating an RTS remote hold the buttons down for at 

least 2 seconds.

The remote is being 

used out of range.

Move within 30ft. of the shade. If the issue persists, adjust the 

antenna to a new position, and make sure the antenna does not 

touch metal.

The remote battery is 

out of place or drained.

Check that the red LED on the remote flashes when buttons 

are pressed. On the installation remote, pry off the back by 

hand and ensure the battery is fully seated in the battery tray. 

If the remote remains unresponsive, replace the battery with a 

CR2430 3V lithium cell.

Tech Support:

 512.832.6939

Содержание Veil Tracks

Страница 1: ...INSTALLERS Please leave this manual with the owner Veil Tracks Installation Instructions 400143 v 1 0 15 February 2021...

Страница 2: ......

Страница 3: ...d Note Track above 16 in length or ordered spliced to save on shipping will need to be connected in the field Mounting brackets type depend on your order Drill with 1 8 bit a Phillips bit Phillips scr...

Страница 4: ...Wall Mount brackets also available for dual track draperies or to extend a single track further from the wall Wall Mounting 2 Ceiling Mounting INSTALLATION BRACKETS STRAIGHT TRACK When determining the...

Страница 5: ...ed depending on ceiling conditions 1 Install the ceiling mount brackets directly over the desired drapery location the far left and right brackets must be atleast 3 75 from the ends of the drapery tra...

Страница 6: ...k is attached by engaging the back row of bracket hooks and pivoting the track past the spring loaded front hooks If needed the hooks can be retracted by pressing the release tab Installation Veil Tra...

Страница 7: ...so the motor and drive pully are in alignment Adjust the sliding motor lock to the right to secure the motor in place you may need to gently twist the motor to fully engage the sliding motor lock Trac...

Страница 8: ...ers and finally attaching to the return hook Note Contact SI Design Services for more help on fabric mounting methods Scan the QR code here to view a short video with additional details INSTALLATION A...

Страница 9: ...ss up or down and the motor will automatically find its limits Step 5 Once the motor stops moving press the up or down button to send the motor to one of its limits Step 6 If the rotation direction is...

Страница 10: ...ut B 485 Additional redudant control via optional one way 485 dongle N A Additional redudant control via optional two way 485 card Zigbee 3 0 N A N A Additional redudant control via optional two way Z...

Страница 11: ...down the program button on the back of the remote the drape will jog 3 Both remotes now control the drape 4 Continue doing this with each drape until all drapes are programmed in the desired groups NO...

Страница 12: ...corner then click Settings 5 Select the SDN tab on the top left 6 Press the spyglass to auto discover motors on the 485 network may have to press it more than once 7 Click on the motor you want to pr...

Страница 13: ...and deselect any other devices 4 Quick press the programming button on the back of the remote and click OK in the application to confirm NOTE Each Zigbee Situo remote channel will be capable of pairi...

Страница 14: ...d motors are operating properly before troubleshooting SI FI network problems Check that the SIFI is communicating on the local network Ping the device via the windows command prompt or make sure the...

Страница 15: ...y connected via ethernet TaHoma LED if OFF No power Check if the USB dongle is properly seated into TaHoma Check the USB is connected to the included power supply and that the AC is on Technical Suppo...

Страница 16: ...Optional keypads Decoflex wirefree 1 5 channel Smoove 1 4 RTS Pure SDN Decoflex 8 button Fontus keypad with Fontus kits Decoflex wirefree 1 5 channel Smoove 1 4 RTS Pure Optional IP controls TaHoma L...

Страница 17: ...Screen Innovations 9715 B Burnet Rd Suite 400 Austin TX 78758 512 832 6939 www screeninnovations com 400143 v 1 0 15 February 2021...

Отзывы: