background image

911-352  Rev. H   10/99 

Page: 1 of 2 

 

SW ITC H

FU SE

FAU C ET

(Typical potable w ater system  show n w ith optional SH U Rflo accessories)

W ATER TAN K

SH U Rflo

PU M P

AC C U M U LATO R

TW IST-LO C K STRAIN ER

1/2" TH READ ED  O R

1/2" BARB IN -LIN E M O D ELS

SH U T-O FF/

W ATER H EATER

C ITY W ATER

W ATER PRESSU RE 

IN -LIN E FAU C ET

AD APTER

W ALL M O U N T M O D ELS

REG U LATO R

FILTERED  W ATER

D RAIN  VALVE

VEN T

O R

*

*

*

*

SC REW

IN -LIN E STRAIN ER

SW IVEL BARB FITTIN G S*

(N o Seal

er Req. D o N ot O verti

ghten)

C O N N EC TO R

O R H EAVIER W IRE

2

(* Included w ith retail pum p ki

ts)

PO TABLE W ATER

IN LET

(15 Am p M in.)

SW ITC H

FU SE

Batt.+

W ITH  # 8 H ARD W ARE

C O AC H FRAM E O R
"KN O W N  G RO U N D "

M O U N T TO  A SO LID  SU RFAC E

(See m otor label for the

recom m ended am p fuse.)

(50 M esh)

Red

Black

(W ater-proof)

# 14 

[2.5 M m   ] 

G AU G E

S

STAIN LESS STEEL 

C LAM PS (2 REQ .)

1

/

2

"

 

I.D .

 FLEXIBLE BRAID ED

 (high psi.)

 

TU BIN G  12 in. LEN G TH S

(recom m ended)

POTABLE WATER PUMP 

Installation and Operation Manual

  

SHURflo has supplied pumps to the manufacturers of RV's for 
over 30 years.  Our patented Tri-a-fram

®

 line of potable water 

pumps deliver smooth, consistent flow at all ranges of operation, 
while drawing low current. The balanced diaphragm design 
incorporates two precision ball bearings for long life. 

 

SHURflo pumps are 

100%

 tested for proper operation before 

they leave the factory. When installed correctly, SHURflo 
water pumps will provide years of quiet operation. 
A SHURflo pump in combination with a low back pressure 
water system can exceed all expectations. For unmatched 
reliability  and trouble-free performance request SHURflo's 
complete line of water system products. 

GENERAL INFORMATION 

SHURflo realizes that in many instances our pump is being installed as a replacement pump within an existing system.  
The following guidelines should be considered to achieve optimum pump operation 

MOUNTING 

 

The pump can be at the same level or below 
the water tank.  It may be positioned above 
the water tank if needed, as it is capable of a 
6 ft. [1.8

M

]

 vertical prime.  Horizontal inlet tubing 

will allow priming to 30 ft. [9

M

]

 

Consider a location that allows easy access 
if maintenance is required.  The pump should 
not be located in an area less than one cubic 
foot unless adequate ventilation is provided.  
Excessive heat may trigger the integral 
thermal breaker and interrupt operation. 

 

When the temperature drops the breaker will 
automatically reset and start operation. 

 

The pump may be mounted in any position. If 
mounting the pump vertically, the pump head should 
be in the down position so that in the unlikely event 
of a leak, water will not enter the motor. 

 

Use 

#

8 hardware to fasten the pump. Choose 

solid

 surface (thick plywood) that will not 

amplify pump operation. The mounting feet 
are intended to isolate the pump from the 
mounting surface; over-tightening, flattening, 
or use of oversized screws will reduce the 
ability to isolate vibration/noise. 

ELECTRICAL 

 

The pump should be on a dedicated (individual) 
circuit, protected by the specified fuse indicated 
on the motor label. 

 

A switch rated at or above 15 amps is 
recommended, and must interrupt current flow 
on the positive (

+

 red)

 lead. Marine applications 

should use U/L  approved marine duty (ignition 
protected)

 switches and pumps.  

 

Wire size (gauge/

M

m

2

)

 is based on the distance 

from the power source to the pump. 
Recommended size wire is 

#

14 gauge [2.5

M

m

2

]

.  

For lengths of 20-50ft. [6-15

M

]

 use 

#

12 gauge 

[4 

M

m

2

]

 

The pump must be grounded to a "known 
ground"  (frame).  The ground wire must be the 
same size (gauge/

M

m

2

)

 as the positive wire. 

 

The total current draw on the circuit 

must not

 

exceed 15 amps. If the pump is used in 
conjunction with other components, overload 
current protection (fuse or circuit breaker) and 
wire size must be for the total amp 
requirement of all devices on the circuit. 

PLUMBING 

 

SHURflo recommends at least 1ft.  [.3

  M

]

 of ½" 

[13mm]

 I.D. flexible high pressure tubing to both 

ports.  Ideally the pumps ports/strainer 

should 

not

 be connected to plastic or rigid pipe. The 

pump's normal oscillation may transmit through 
rigid plumbing causing noise, and possibly 
loosen or crack components. 

 

Installation of a 50 mesh strainer (SHURflo P/N 
170) 

is recommended to prevent foreign debris 

from entering the pump.  

 

SHURflo swivel barb fittings provide easy 
removal if maintenance or access is required. 
The fittings are designed with a "taper-seal", 
creating a water tight connection when 

hand-

tightened

.  

Neve

r

 use Teflon tape or sealing 

compounds on threads.  Sealer may enter the 
pump causing a failure.  

Failure due to foreign 

debris is not covered under warranty

Always secure barb tubing connections with 
properly sized stainless steel clamps to 
prevent leaks. 

 

Rapid cycling may be caused by excessive 
back pressure created by one or more of the 
following within a plumbing system: 

    

Water filters not on separate feed lines. 

    

Flow restrictors in faucets and shower heads. 

    

Small I.D. lines. Pipe/tubing should be at 

least ½" [13mm] I.D. for main lines. 

    

Restrictive fittings and connections (elbows, 

"T's", feeder lines to faucets, etc.)

 

 

SWITCH SHUT-OFF 

Restrictions in a plumbing system may cause the 
pump to rapid cycle (ON/OFF within 2 sec.) during 
low flow demands. Cycling should be minimized 
to prevent pulsating flow, and to achieve 
maximum pump life. 
To determine if adjustment is necessary, turn a 
faucet 

ON

 to lower than average flow of water.  

The pump should cycle, but its "

OFF

 time" must 

be 2 sec. or longer.  If the cycling is correct, 
leave well enough alone.  If the pump is cycling 
rapidly increase the setting by turning the screw 
clockwise (1½ turn 

MAX

.)

 until the pump operates 

for 1 sec. with at least 2 sec. "

OFF

 time".  If 

cycling cannot be minimized consider removing 
plumbing restrictions or simply install a 
SHURflo Accumulator. 