background image

LILIE GmbH & Co. KG   Heinrich-Hertz Straße-30   D-74354 Besigheim   Germany 

Tel. +49 (0)7143 9623-0   Fax +49 (0)7143 9623-23   [email protected]   www.lilie.com

Seite 3

 

Stand 16.01.2019 / # E-6103_A-en / 11 / 04.2019 

© LILIE GmbH & Co. KG 

Subject technical changes

DESINFECTION AND MAINTENANCE

 

DISINFECTION
It is recommended to disinfect the entire drinking water system with LILIE-drinking water-disinfectant once a year, more frequently by intensive 
use. The LILIE-drinking water -disinfectant is approved in Germany according to §11 of the Drinking Water Ordinance for drinking water treatment. 
We recommend the following method, especially for the determination of the required quantity:
1.  Add the appropriate amount of LILIE-drinking water -disinfectant (1 bottle #56200 = 1 liter for 100 liters of water) to the tank and fill up 

with fresh water.

2.  Open all taps.
3.  Turn on the pump with the main switch.
4.  Close all taps when water is running out of all water taps. The pump shuts off automatically.
5.  For sufficient disinfection, the solution should remain in the system / tank for 6 hours
6.  After the contact time is up drain the tank by opening the water taps.
7.  Refill the system with fresh water and rinse the disinfectant solution from the entire piping system.
NOTE: The disinfection method described here complies with the German Drinking Water Ordinance, in accordance with DIN-2001-2, which is also 
valid for the entire EU.

MAINTENANCE
Drinking water systems require regular maintenance to ensure a steady flow of drinking water. The following measures should be carried out 
regularly: 
• 

Checking and cleaning the coarse filter.

• 

Occasional cleaning / disinfecting of pipes.

• 

Checking screw and bolt fittings for leaks or cracks.

If there is a risk of frost, the pump and the pipes should be protected against freezing. (i.e., by draining or filling with suitable antifreeze, e.g., 
LILIE article # 56601 Winter Ban.) Lack of maintenance is one of the most common causes of power loss and premature failure of the pump. Debris 
on valves and diaphragms can lead to pressure loss or internal leakage over time. (I.e., recognizable by random short startup of the pump, even 
though no load is active.)
To take relevant measures regarding this matter please refer to your RV or Motorhome manufacturer for more information!

WINTERIZING THE PUMP

 

If water freezes in the hose- or pipelines, the pump and the pipes can be damaged. Failures of this kind shall release us from any warranty ser-
vices and/or coverage. The best protection against such frost damage is to make sure to drain the water completely. However, non-toxic antifree-
ze for fresh water, may also be used (e.g., LILIE article # 56601 winter ban). This is obtainable at any mobile home store or department.
Winter break with antifreeze requires special protections, because at temperatures below 0 degrees the water system freezes and is damaged if it 
still contains water.
1.  Open all taps and empty the tank completely.
2.  Close all taps.
3.  Add at least 10 liters of winter ban/water mixture to the tank.
4.  Then open the water taps until colored liquid emerges.
5.  Close all water taps and turn off the pump main switch.
CAUTION:
Don’t use automotive antifreeze to stabilize drinking water pipelines in winter. These solutions are highly toxic. If such a solution is swallowed, it 
can lead to injury or death.

Antifreeze Winter Ban 3.78l

# 56601

Mixing ratio (3.8l each)

Protects against frost damage, corrosion, 
deposits and algae growth at outdoor tem-
peratures of up to -73°C and also lubricates 
pumps and valves. For pipes and devices 
made of brass and plastics. Nontoxic, taste-
less and odorless. Market leader in the US, 
EU-compliant with UBA approval. Trilingual 
label with detailed instructions.

Winter 
Ban 

Water

Protec-
tion up 
to 

total 
quantity

1 x 

4

-10° C

18.9 l

1 x

2

-20° C

11.3 l

1 x

1.5

-30° C

9.5 l

1 x

1

-38° C

7.6 l

1 x

0.5

-52° C

5.7 l

1 x

0

-73° C

3.8 l

water tank 

water tank 

pipes  

without  

Winter Ban

pipes with  

Winter Ban

LILIE-drinking water-disinfectant

# 56200

   Suitable for containers, hose- and pipe systems

   Easy to dose and to apply.

   works on basis of a stabilized hydrogen peroxide solution and  

complies with the processing materials approved by the  
Federal Environment Agency for the disinfection of drinking water  
and corresponds with the dosage recommendation.

   residue-free and quickly biodegradable

   Protects the used drinking water approved materials

   Colorless, odorless and tasteless.

   The content of 1 liter is enough to disinfect 100 liters of drinking water with a mini-

mum exposure time of 6 hours. For smaller tanks the exposure time can be propor-
tionally reduced, for larger tanks use 2 or more bottles.

Content: 1000 ml, for 100 liters of drinking water
Stabilized hydrogen peroxide solution 3%, bottle: H240 x W90 x D90 mm, 1040 g

Water

LILIE-drinking water-

disinfectant 

minimum  

exposure time

100 liters

1 bottle

6 hours

200 liters

1 bottle

12 hours

250 liters

1 bottle

15 hours

100 liters

2 bottles

3 hours

Содержание Lilie Classic Series

Страница 1: ...g maintenance Use suitable flexible pressure resistant hoses in the input and output of the pump e g our LILIE Native No rigid plastic or metal piping should be used for the pump input and output as well as the coarse filter Otherwise the operating vibrations of the pump can be amplified which can lead to loud operating noise as well as cavitation leaks or even defects on other components Use only...

Страница 2: ...d be used at the inlet and outlet of the pump To reduce vibrations and their transmission this tubing should have a support at the junction to rigid tubing The pump and coarse filter should not be rigidly tubed ADJUSTING THE PRESSURE SWITCH The Pressure switch and Bypass are factory preset In general no adjustment should be required If your specific operating conditions require this please proceed...

Страница 3: ...an be damaged Failures of this kind shall release us from any warranty ser vices and or coverage The best protection against such frost damage is to make sure to drain the water completely However non toxic antifree ze for fresh water may also be used e g LILIE article 56601 winter ban This is obtainable at any mobile home store or department Winter break with antifreeze requires special protectio...

Страница 4: ...heck the pipes on the output side pressure for leaks Also check for leaky valves and the toilet Check if air bubbles are enclosed in the output side continuous flow water heater or in the pump head Ensure that the voltage 10 to the pump is correct Check for loose screws in the drive assembly or pump head Are the valves or integrated check valves held in place by solids or is the rubber macerated C...

Страница 5: ...anty if for example a caravanning pump is used outdoors The pumps do not prove to protect against water according to IP ff Solely pumps for boats are designed for the application in seawater environments However this does not mean that can be used standing vertically or horizontally in water We assume no guarantee for defects resulting from an unsuitable or improper appli cation or operation This ...

Страница 6: ...S4122 11202 for LS4142 LS4143 LS4144 11212 for LS4242 Ready to connect complete motor with 4 point base plate and connection cables and CLASSICSERIE Pressure Switch 11139 for LS204 LS473 11109 for LS061 LS403 Pressure Switch with pump housing upper part The shut off pressure is ad justable 11139 from 1 1 to 2 1 bar 11109 from 2 to 3 2 bar LM T101 PP LM T105 TPE CLASSICSERIE Pump Head complete 1113...

Отзывы: