REPLACEMENT PARTS

To ensure that you receive the correct spare parts, please specify the defect component, the complete model number, date of manufacture 
and the indications on the nameplate, when placing the order. Parts kits contain comprehensive repair instructions.

SOFT

SERIE

®

-

Pump Head complete

# 11231 

for LS4121

# 11221 

for LS4142, LS4242

# 11251 

for LS4144

Pressure Switch with pump housing  
upper part and integrated bypass,  
diaphragm kit and valve kit. The shut-off 
pressure is adjustable: #11231 from  
1.4 to 2.4 bar, #11221 from 1.7 to  
2.8 bar, #11251 from 3.0 to 3.6 bar
LM T101 (PP), LM T105 (TPE), LM T107 (EPDM)

SOFT

SERIE

®

-Diaphragm kit

# 11205 

for LS4121, LS4142, LS4242, LS4144
Diaphragm kit complete with pump 
housing base and motor mount.
LM T105 (TPE), LM T101 (PP)

SOFT

SERIE

®

-Valve kit

# 11204 

for LS4121, LS4142, LS4242, 
LS4144
LM T107 (EPDM), LM T101 (PP)

SOFT

SERIE

®

-

Pressure Switch 

# 11239 

for LS4121, LS4122

# 11229 

for LS4142, LS4242, LS4143

# 11209 

for LS4144

Pressure Switch with pump housing 
upper part with integrated bypass. The 
shut-off pressure is adjustable: #11239 
from 1.4 to 2.4 bar, #11229 from 1.7 to 
2.8 bar, #11209 from 3.0 to 3.6 bar

LM T101 (PP), LM T105 (TPE)

SOFT

SERIE

®

-Motor complete

# 11232 

for LS4121, LS4122

# 11202 

for LS4142, LS4143, LS4144

# 11212 

for LS4242

Ready-to-connect complete motor with 
4-point base plate and connection cables 
+ and -.

CLASSIC

SERIE

Pressure Switch 

# 11139 

for LS204, LS473

# 11109 

for LS061, LS403

Pressure Switch with pump housing 
upper part. The shut-off pressure is ad-
justable: #11139 from 1.1 to 2.1 bar, 
#11109 from 2 to 3.2 bar

LM T101 (PP), LM T105 (TPE)

CLASSIC

SERIE

Pump Head complete

# 11131 

for LS204, LS473

# 11121 

for LS061

# 11101 

for LS403

Pressure Switch with pump housing 
upper part, diaphragm kit and valve 
kit. The shut-off pressure is adjustable: 
#11131 from 1.1 to 2.1 bar, #11121 
from 2.1 to 3.5 bar, #11101 from 2 to 
3.2 bar
LM T101 (PP), LM T105 (TPE), LM T107 (EPDM)

CLASSIC

SERIE™-Diaphragm kit

# 11105 

for LS061, LS204, LS403, LS473, LS512, 
LS423, LS224, LS573, LS534, LS572
Diaphragm kit complete with pump 
housing base and motor mount.
LM T101 (PP), LM 105 (TPE)

CLASSIC

SERIE™-Valve kit

# 11104

for Models LS061, LS204, LS403, 
LS473 und für LS512, LS573, LS572, 
LS534, LS423, LS224 up to year of 
construction 2008.

LM T101 (PP), LM T107 (EPDM)

CLASSIC

SERIE

-Motor complete

# 11132 

for LS204

# 11142 

for LS224

# 11102 

for LS403

# 11112 

for LS473

Ready-to-connect complete motor with 
4-point base plate and connection cables 
+ and -.

SOFT

SERIE

®

:

1

  Pressure switch  

with pump housing upper part and integrated bypass 

2

 Valve kit

3

  Diaphragm kit  

with pump housing base

5

 Motor (-group)

Complete pump-head assembly  
(consisting of parts-no.: 1,2 and 3)

CLASSIC

SERIE

:

2

 Valve kit

3

  Diaphragm kit  

with pump housing base

Complete pump-head assembly  
(consisting of parts-no.: 1,2 and 3)

1

  Pressure switch  

with pump housing upper part 

5

    Motor (-group)

1

1

3

3

2

2

4

4

5

5

4

4

Содержание Lilie Classic Series

Страница 1: ...g maintenance Use suitable flexible pressure resistant hoses in the input and output of the pump e g our LILIE Native No rigid plastic or metal piping should be used for the pump input and output as well as the coarse filter Otherwise the operating vibrations of the pump can be amplified which can lead to loud operating noise as well as cavitation leaks or even defects on other components Use only...

Страница 2: ...d be used at the inlet and outlet of the pump To reduce vibrations and their transmission this tubing should have a support at the junction to rigid tubing The pump and coarse filter should not be rigidly tubed ADJUSTING THE PRESSURE SWITCH The Pressure switch and Bypass are factory preset In general no adjustment should be required If your specific operating conditions require this please proceed...

Страница 3: ...an be damaged Failures of this kind shall release us from any warranty ser vices and or coverage The best protection against such frost damage is to make sure to drain the water completely However non toxic antifree ze for fresh water may also be used e g LILIE article 56601 winter ban This is obtainable at any mobile home store or department Winter break with antifreeze requires special protectio...

Страница 4: ...heck the pipes on the output side pressure for leaks Also check for leaky valves and the toilet Check if air bubbles are enclosed in the output side continuous flow water heater or in the pump head Ensure that the voltage 10 to the pump is correct Check for loose screws in the drive assembly or pump head Are the valves or integrated check valves held in place by solids or is the rubber macerated C...

Страница 5: ...anty if for example a caravanning pump is used outdoors The pumps do not prove to protect against water according to IP ff Solely pumps for boats are designed for the application in seawater environments However this does not mean that can be used standing vertically or horizontally in water We assume no guarantee for defects resulting from an unsuitable or improper appli cation or operation This ...

Страница 6: ...S4122 11202 for LS4142 LS4143 LS4144 11212 for LS4242 Ready to connect complete motor with 4 point base plate and connection cables and CLASSICSERIE Pressure Switch 11139 for LS204 LS473 11109 for LS061 LS403 Pressure Switch with pump housing upper part The shut off pressure is ad justable 11139 from 1 1 to 2 1 bar 11109 from 2 to 3 2 bar LM T101 PP LM T105 TPE CLASSICSERIE Pump Head complete 1113...

Отзывы: