TROUBLESHOOTING

 

Shocks and vibrations or transportation can loosen the piping system and parts of the pump. Check for loose system components. Various 
symptoms can be fixed without difficulties through tightening of small parts. Check the following items along with other details of the 
system. 

THE PUMP DOESN’T START / TRIGGERS OVERLOAD SWITCH:
• 

Check the circuit connections, fuse or overload switch, power switch, and the ground line.

• 

Is the motor hot? The thermo-switch might have been triggered. It will reset after cooling.

• 

Is there voltage on the switch? Bypass the pressure switch. Does the pump work?

• 

Check charging system for correct voltage (+/- 10%) and proper grounding.

• 

Check for an open or grounded circuit, motor or wires with incorrect thickness.

• 

Check for blocked or stuck diaphragm/component (ice formation?).

THE PUMP DOESN’T SUCK / STUTTERS:
(No drainage/motor runs)
• 

Is the screen filter blocked?

• 

Is the tank filled with water or are there air bubbles enclosed in the continuous-flow water heater?

• 

Does the inlet tube/the piping system suck up air at the pipe connections (vacuum leak)?

• 

Is the inlet/outlet pipe constricted significantly or kinked?

• 

Correct voltage while the pump is operating (+/- 10%).

• 

Check for solids in the inlet/outlet valves or connecting valves.

• 

Check the pump housing for cracks or loose screws in the input unit.

PUMP DOESN’T SWITCH OFF / KEEPS RUNNING WITH CLOSED FAUCET:
• 

Check the pipes on the output side (pressure) for leaks. Also, check for leaky valves and the toilet.

• 

Check if air bubbles are enclosed in the output side (continuous-flow water heater) or in the pump head.

• 

Ensure that the voltage (+/-10%) to the pump is correct.

• 

Check for loose screws in the drive assembly or pump head.

• 

Are the valves or integrated check valves held in place by solids or is the rubber macerated?

• 

Confirmation of the pressure switch/wrong setting => refer to the section „Setting the pressure switch“.

• 

SOFT

SERIES

®

 / Bypass Pumps: Check bypass / Pressure switch settings.

LOUD OR IRREGULAR OPERATION:
• 

Check if the hoses and pipeline have become loose.

• 

Is the pump connected to pipes/wires through which noises could be transmitted?

• 

Are the noises enhanced by the installation surface (flexible)?

• 

Check if the mounting feet are compressed too tightly or have become loose.

• 

Check for loose screws at the connection between the pump head and the motor (3 long screws).

• 

Does the noise originate from the engine or the pump head? (The engine with pump head taken off).

• 

Flow-rate in the system is not 100%? Is the pump stuttering? If necessary, use a pressure equalization tank or a pump of the  

SOFT

SERIE

®

 or 

SMART

SERIE™.

RAPIDLY SWITCHING ON AND OFF
• 

Check the settings of the pressure switch.

• 

Water filter/water purifier should be connected to separate supply lines.

• 

Check for hoses or pipelines with constrictions. Check the flow restrictor in the faucets and in the shower heads.

• 

Flow-rate in the system is not 100%? Is the pump stuttering? If necessary, use a pressure equalization tank or a pump of the  

SOFT

SERIE

®

 or 

SMART

SERIE™.

LEAKY SPOTS ON PUMP HEAD OR SWITCH
• 

Check for loose screws on the switch and pump head.

• 

Switch diaphragm ruptured or pierced?

• 

Check for ruptured or punctured diaphragm in case there is water inside the drive assembly.

Содержание Lilie Classic Series

Страница 1: ...g maintenance Use suitable flexible pressure resistant hoses in the input and output of the pump e g our LILIE Native No rigid plastic or metal piping should be used for the pump input and output as well as the coarse filter Otherwise the operating vibrations of the pump can be amplified which can lead to loud operating noise as well as cavitation leaks or even defects on other components Use only...

Страница 2: ...d be used at the inlet and outlet of the pump To reduce vibrations and their transmission this tubing should have a support at the junction to rigid tubing The pump and coarse filter should not be rigidly tubed ADJUSTING THE PRESSURE SWITCH The Pressure switch and Bypass are factory preset In general no adjustment should be required If your specific operating conditions require this please proceed...

Страница 3: ...an be damaged Failures of this kind shall release us from any warranty ser vices and or coverage The best protection against such frost damage is to make sure to drain the water completely However non toxic antifree ze for fresh water may also be used e g LILIE article 56601 winter ban This is obtainable at any mobile home store or department Winter break with antifreeze requires special protectio...

Страница 4: ...heck the pipes on the output side pressure for leaks Also check for leaky valves and the toilet Check if air bubbles are enclosed in the output side continuous flow water heater or in the pump head Ensure that the voltage 10 to the pump is correct Check for loose screws in the drive assembly or pump head Are the valves or integrated check valves held in place by solids or is the rubber macerated C...

Страница 5: ...anty if for example a caravanning pump is used outdoors The pumps do not prove to protect against water according to IP ff Solely pumps for boats are designed for the application in seawater environments However this does not mean that can be used standing vertically or horizontally in water We assume no guarantee for defects resulting from an unsuitable or improper appli cation or operation This ...

Страница 6: ...S4122 11202 for LS4142 LS4143 LS4144 11212 for LS4242 Ready to connect complete motor with 4 point base plate and connection cables and CLASSICSERIE Pressure Switch 11139 for LS204 LS473 11109 for LS061 LS403 Pressure Switch with pump housing upper part The shut off pressure is ad justable 11139 from 1 1 to 2 1 bar 11109 from 2 to 3 2 bar LM T101 PP LM T105 TPE CLASSICSERIE Pump Head complete 1113...

Отзывы: