Successful use of water pressure diaphragm pumps

CLASSIC

SERIE™ and 

SOFT

SERIE

®

GENERAL INFORMATION

Enjoy your LILIE water pump for years to come! 
For us at LILIE, the most important thing is customer satisfaction.
With this product you have acquired a great pump that we have developed in over 30 years. It is made of special materials which comply 
with the drinking water ordinance according to DIN 2001-2.
Please use your new pump only corresponding to this manual! If you do so, you will be able to reliably enjoy our products long-term, like 
the other hundreds of thousands of satisfied customers.
Please note:
Caravaning pumps are developed for application in the dry interior of a motor home. They are not splash-proof or acid-resistant. The 
pumps have no splashguard according to IP ff. Our Boat pumps are constructed for use in seawater environments. However, that does not 
mean they can be used standing or submerged in water. No warranty shall be accepted for damage caused by inappropriate or improper 
use or operation, or faulty installation. This includes continuous operation. These pumps are not suitable for continuous or permanent use 
but have been specially developed for intermittent operation.
The power-on time and interval lengths of the pump in use depend according to the specifications in our current catalogue. A caravanning-
pump, e.g., may run smoothly for up to 20 minutes, after which a longer pause is necessary. (Generally, the fresh-water tank of your motor 
home would already be empty.)

It is very important to tighten the screws, which may have become loose by cause of vibrations and movements, from time to time. Check 
the screw fittings regularly; many problems can be solved or avoided this way.

INSTALLING THE PUMP

The aim of the installation is to achieve the most silent pump operation, with efficient conveying behavior, the lowest possible pressure load, 
and easy access to maintenance work. By following the instructions below, these results can be achieved.
The pump should be installed on a stable surface with sufficient accessibility, for easy access to the coarse filter during maintenance.
• 

Use suitable flexible pressure-resistant hoses in the input and output of the pump, e.g. our LILIE Native.

• 

No rigid, plastic or metal piping should be used for the pump input and output, as well as the coarse filter.

• 

Otherwise, the operating vibrations of the pump can be amplified, which can lead to loud operating noise as well as cavitation, leaks, 
or even defects on other components. 

• 

Use only original grommets (e.g. LILIE 12mm: #8042, #8044; 10mm: #8040, #8043) without further use of Teflon tape or another sea-
lant. The use of these means, as well as the use of other connections, can lead to leaks or damage to the pump. Such damage is not 
covered by the warranty of the pump.

• 

On the input side, the pump should be protected by a suitable coarse filter (50-mesh, mesh size approximately 0.25mm, e.g., LILIE # 
LS200162) to prevent particles from entering.

• 

Mount the pump on a stable surface to avoid vibration and noise.

• 

Hose lines should have an inner diameter of ideally at least 12 mm. We recommend our LILIE Native Drinking Water Hose #88112 or 
#98112. Smaller pipe diameters can lead to cavitation, increased pressure resistance, reduced flow and an increase in operating 
noise.

• 

Please avoid restrictions on the diameter of the plumbing at the inlet and outlet side of the pump as much as possible. 

• 

This also applies to shut-off and drain valves, as well as angle connectors with smaller inner diameter.

• 

You don’t need a pressure compensation tank when using a pump of the 

SOFT

SERIE

®

 or 

SMART

SERIE

.

• 

This pump is designed for intermittent use only. Don’t use the pump for a reverse osmosis system. High pressure and non-stop opera-
tion shorten the life cycle of the pump. Such use is not covered by the warranty.

• 

The diameter of the cables should be 1.5mm² at minimum; we recommend 2.5mm² or 4.0mm². (See respective diagram in section 
“Electrical Connection”)

• 

If your motor home has any control device (such as LILIE article #18501) installed, it has to be designed to meet the pump’s maximum 
power consumption.

• 

In order to achieve best the possible performance and operational lifetime of the pump, mount it within a distance of maximum 2m 
from the fresh water tank.

• 

In order to properly ventilate and protect against overheating, the pump should be mounted at a location with 20l (0.02 m

3

) or more of 

free space. 

• 

The pump can be mounted in a vertical or horizontal position. If mounted in a vertical position the pump-head must be pointed down-
wards.

• 

The installation site should be easily accessible to facilitate maintenance work such as emptying the coarse filter.

by

Содержание Lilie Classic Series

Страница 1: ...g maintenance Use suitable flexible pressure resistant hoses in the input and output of the pump e g our LILIE Native No rigid plastic or metal piping should be used for the pump input and output as well as the coarse filter Otherwise the operating vibrations of the pump can be amplified which can lead to loud operating noise as well as cavitation leaks or even defects on other components Use only...

Страница 2: ...d be used at the inlet and outlet of the pump To reduce vibrations and their transmission this tubing should have a support at the junction to rigid tubing The pump and coarse filter should not be rigidly tubed ADJUSTING THE PRESSURE SWITCH The Pressure switch and Bypass are factory preset In general no adjustment should be required If your specific operating conditions require this please proceed...

Страница 3: ...an be damaged Failures of this kind shall release us from any warranty ser vices and or coverage The best protection against such frost damage is to make sure to drain the water completely However non toxic antifree ze for fresh water may also be used e g LILIE article 56601 winter ban This is obtainable at any mobile home store or department Winter break with antifreeze requires special protectio...

Страница 4: ...heck the pipes on the output side pressure for leaks Also check for leaky valves and the toilet Check if air bubbles are enclosed in the output side continuous flow water heater or in the pump head Ensure that the voltage 10 to the pump is correct Check for loose screws in the drive assembly or pump head Are the valves or integrated check valves held in place by solids or is the rubber macerated C...

Страница 5: ...anty if for example a caravanning pump is used outdoors The pumps do not prove to protect against water according to IP ff Solely pumps for boats are designed for the application in seawater environments However this does not mean that can be used standing vertically or horizontally in water We assume no guarantee for defects resulting from an unsuitable or improper appli cation or operation This ...

Страница 6: ...S4122 11202 for LS4142 LS4143 LS4144 11212 for LS4242 Ready to connect complete motor with 4 point base plate and connection cables and CLASSICSERIE Pressure Switch 11139 for LS204 LS473 11109 for LS061 LS403 Pressure Switch with pump housing upper part The shut off pressure is ad justable 11139 from 1 1 to 2 1 bar 11109 from 2 to 3 2 bar LM T101 PP LM T105 TPE CLASSICSERIE Pump Head complete 1113...

Отзывы: